CONTROL PORTS AND PROTOCOLS -
continued
Multiple Conditions
The GPO active state may be conditional on more than one
occurrence.
The rightside buttons F1R to F4R set-up the conditions and
the way they combine to produce an active output.
F2R Add Condition
Pressing this button adds another condition to the original
single condition. One or two extra conditions may be added.
When a second condition is added they are titled Cond 1 and
Cond 2, another addition becomes Cond 3.
F1R Next Condition
When there are two or three conditions this button is used to
step through them. The active one has green text whereas the
other(s) have white.
F3R Remove Condition
This button removes the currently active condition and
renumbers the others if neccessary.
Each condition is programmed independently of the others.
Select the condition with F1R and use the rotary controls as
detailed previously.
Combining Conditions
The GPO will be active when the combination of conditions
conforms to a specified state. The combination state is
selected by F4R (Combination) which steps through those
available.
For two conditions the states are [C1 and C2] or [C1 or C2].
With three conditions there are four available states they are:
[C1 and C2 and C3], [C1 or C2 or C3], [(C1 and C2) or C3] or
[(C1 or C2) and C3].