CONTROL PORTS AND PROTOCOLS -
continued
S & W Tally
This protocol transmits detailed tally information every field for use by external intelligent tally
systems. The protocol used is specific to Snell & Wilcox, and details are available on request.
S & W
Router & S & W
Router No Aux
For use with Snell & Wilcox HD1132 router.
Remote Panel 8 & Remote Panel 16
Allows remote control of M/E 1 on 2.5M/E & 3M/E Switchers using a CP8 or CP16 panel.
Aux Control Quartz & Aux Control ProBel
Allows remote source allocation of the Aux outputs using a Quartz or ProBel remote panel.
Probel TX320 & DVE
These are proprietary protocols.
BBC Camera
This is a proprietary protocol for use with virtual studio software.
Button Bus
The address code of the pressed control panel button is sent from the applicable port.
B-Bus Multi Ctl
Allows one control panel to control two mainframes in parallel, i.e., a SD & HD system.
P-Bus
Allows up to 32 RS-485 devices to be strung off a port and triggered independently.
Router Protocols
Allows a variety of third party Integrated and/or Pre-Selecting routers to be used with the HD1024.
Select the appropriate control protocol for a Pre-Select router (if used) and the Integrated router (if
not the S&W HD1132) from the available router protocols, see table below.
Router Model
Protocol for Integrated use
Protocol for Pre-Selecting use
Pro-Bel HD Sirius
Fast Simple Rtr
Pre ProBel Rtr
Pro-Bel HD
ProBel Router
Pre ProBel Rtr
PESA Cheetah HD
N / A
Pre PESA Rtr
PESA Cougar HD
N / A
Pre PESA Rtr
NVision HD series
N / A
Pre NVision Rtr