www.snellwilcox.com
S&W Production & Post Production
HD1012 Installation Manual – V3, Issue 1, Rev 1
Page 5
SYSTEM INTERCONNECTION
Introduction
Your system has been set up and tested before shipment. Installation normally consists of siting
and interconnecting the system components, connecting video and key inputs and outputs and
setting up.
Control Panel
Remove and keep the supplied nuts and washers from the two bolts on the top of the Control
Panel. Remove the LCD Touch Screen module from the packaging. Carefully fit it over the two
bolts on the top of the Control Panel. Place the LCD Touch Screen’s earth strap over the nearest
bolt, then fix down the LCD Touch Screen using the washers and nuts that you removed earlier.
Connect the 25-pin D connector to the similar one on the rear of the Control Panel using the cable
provided.
Connect the 9-way D connector to the similar one on the rear of the Control Panel using the cable
provided.
If desired, a standard VGA monitor can be plugged into the 15-way sub-D connector at the bottom
rear of the panel. The signal frequency is 39.06kHz Horizontal and 62.5Hz Vertical and should be
acceptable to most (but not all) SVGA-compatible monitors.
Finally, connect the 10 Base-T connector on the Control Panel to the socket on the Switcher
Mainframe marked “
Panel 10 BASE TX
” using the cable provided.
Connecting to an Alternate Mainframe
The CP1524 Control Panel can be used to control another (Alternate) mainframe, e.g., a SD
system. The IP address of the alternate mainframe is set in the Miscellaneous - IP Address menu.
The alternate mainframe is connected to the primary mainframe via the 10 BASE T sockets.
Connect the 10 BASE T socket on the rear panel of the mainframe (adjacent to the Panel 10 BASE
TX connector) to the Panel 10 BASE TX socket on the alternate mainframe.
Power
Switch all power switches to their OFF states. Connect IEC power cables from the power socket(s)
on the rear of the Switcher Mainframe and Control Panel to the appropriate AC mains distribution
socket(s).
The HD1000 mainframe has a shutdown switch for each power supply behind the front door on the
left hand side.
When the power supply is shut down, the red light in the shutdown button will
illuminate.