background image

INSTALLATION MANUAL

Summary of Contents for HD1012

Page 1: ...INSTALLATION MANUAL ...

Page 2: ...reinafter granted including without limitation material generated from the software programs which are displayed on the screen such as icons screen display looks etc Information in this manual and software are subject to change without notice and does not represent a commitment on the part of Snell Wilcox Ltd The software described in this manual is furnished under a license agreement and may not ...

Page 3: ...s unless you are qualified to do so Refer all servicing to qualified personnel WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE Always ensure that the unit is properly earthed and power connections correctly made This equipment must be supplied from a power system providing a PROTECTIVE EARTH connection and having a neutral connection which can be relia...

Page 4: ...llows GREEN YELLOW lead connected to E Protective Earth Conductor BLUE lead connected to N Neutral Conductor BROWN lead connected to L Live Conductor Free Socket Free Plug Control Panel Power cable tie A cable tie mount is located by the power inlet on the control panel A cable tie may be used to fix the power cable to the unit to prevent accidental disconnection of power If this facility is used ...

Page 5: ...om Cooling Fan Failure IF THE COOLING FANS AT THE REAR OF THE SD1000 SWITCHER MAINFRAME SHOULD STOP FOR ANY REASON THEN THE SYSTEM SHOULD BE SWITCHED OFF IMMEDIATELY OR PERMANENT DAMAGE MAY RESULT Depending on the length of time the mainframe has been run with no fan the unit may need to be returned for checking and repair Contact Snell and Wilcox or your Snell and Wilcox dealer to discuss the sit...

Page 6: ...urpose built broadcasting or recording studios and the rural outdoor environment far away from railways transmitters overhead power lines etc E4 EMC Performance of Cables and Connectors Snell Wilcox products are designed to meet or exceed the requirements of the appropriate European EMC standards In order to achieve this performance in real installations it is essential to use cables and connector...

Page 7: ...L PORTS AND PROTOCOLS 14 Ports 14 FTP Connecting to a PC 14 GVG 100 14 GVG 4000 15 Sony DVS 16 Using a Sony BVE 9100 Editor 18 VTR 20 Follow Real VTR 20 S W Tally 21 Aux 21 Probel TX320 DVE 21 BBC Camera 21 Button Bus 21 P Bus 21 Router Protocols 21 General Purpose Inputs Outputs 22 The Inputs 22 The Outputs 23 Programming the Inputs 24 Programming the Outputs 25 Multiple Conditions 26 List of GPO...

Page 8: ... Mode Connections 11 Pro Bel Panel Button Functions 29 Quartz Panel Button Functions 30 Diode Buffer 32 Aux Control Interconnections 33 Integrated Router Connections 39 LIST OF TABLES Line Standard Timing Information 12 System Delay Timings 13 GVG 4000 Crosspoints 15 GVG 4000 bus assignments 16 Sony DVS bus assignments 16 Sony DVS Crosspoints 17 Follow Real VTR connector pinouts 20 Router Protocol...

Page 9: ...www snellwilcox com S W Production Post Production HD1012 Installation Manual V3 Issue 1 Rev 1 Page 1 SECTION A INSTALLATION ...

Page 10: ...incorrect notify your dealer or Snell and Wilcox directly at once 2 Check that the equipment has not been damaged in transit If any damage has occurred notify your dealer or Snell and Wilcox directly at once as well as the carrier 3 Always retain the original packing materials if possible they could prove useful should it ever be necessary to transport or ship the system units The system component...

Page 11: ...m 8 inches is ESSENTIAL b The slots in the front panel are to allow the inlet of cooling air and MUST NOT BE OBSTRUCTED c When mounting the mainframe in an equipment rack it MUST be supported at the rear not by the rack mounting ears alone Cooling is provided by drawing air in at the front of the unit and exhausting it at the rear The mainframe should never be operated for any significant period o...

Page 12: ...power supply connected if required For safety a mains earth connection MUST be provided Control Panel The control panel is protected by a 4 amp anti surge slow blow fuse located in the mains inlet power switch assembly see diagram below E Protective Earth Conductor N Earthed Neutral Conductor L Phase Conductor Mainframe The mainframe is protected by an internal fuse that is not user replaceable E ...

Page 13: ...b D connector at the bottom rear of the panel The signal frequency is 39 06kHz Horizontal and 62 5Hz Vertical and should be acceptable to most but not all SVGA compatible monitors Finally connect the 10 Base T connector on the Control Panel to the socket on the Switcher Mainframe marked Panel 10 BASE TX using the cable provided Connecting to an Alternate Mainframe The CP1524 Control Panel can be u...

Page 14: ...acility may be used to allow one control panel to control two mainframes simultaneously using the function Button Bus Multi Control To use this facility ensure that both mainframes have the same set up and are in the same operational situation otherwise problems will arise when using certain control buttons such as toggle functions Set one of the serial ports on each of the two mainframes to B Bus...

Page 15: ...anual V3 Issue 1 Rev 1 Page 7 SYSTEM INTERCONNECTION continued DISPLAY 2 DISPLAY 1 VGA MAINFRAME 10 BASE T RS232 MODEL No SE RIAL No MADE IN SAFFRON WALDEN ESSEX UK S NELL WILCOX 115 230V 60 50Hz 1 0 0 5A T 250V 5A Control Panel Rear View Control Panels Top Connector Plate ...

Page 16: ...www snellwilcox com Page HD1012 Installation Manual V3 Issue 1 Rev 1 S W Production Post Production 8 SYSTEM INTERCONNECTION continued CP1512 Dimensions in mm 819 824 ...

Page 17: ...www snellwilcox com S W Production Post Production HD1012 Installation Manual V3 Issue 1 Rev 1 Page 9 SYSTEM INTERCONNECTION continued HD1000 Switcher Mainframe Rear Panel Connectors ...

Page 18: ...e system and transition previews Preview 2 Preview 2 is a second preview output with similar capabilities to the first except that it cannot preview mixer transitions The Preview 1 output is also available in Analogue Component as either YPbPr or RGB Whether YPbPr or RGB format is used can be selected in the Configure System Genlock Outputs menu R G B and Y outputs have syncs If the monitor requir...

Page 19: ...Setup menu Clean Preview 1 Program M E Preview M E Program P P Preview DSK Program HD1000 Preview 2 The Clean Output button F2R allows the signal on the Clean Program O P to be switched between Clean DSK and DSK Pvw This button is NOT used in the above Multi Monitor Mode F1R Multi Pvw toggles between Enabled and Disabled when in Enabled the Clean Output button does not function and the signal on t...

Page 20: ...y adjusting a the Genlock H V Phase controls when the switcher is not the Master SPG b the genlock controls of the source equipment and or c the Ref Sync Output s Sync H V Phase controls These controls can be found in the Configure System Genlock Outputs sub menu see User Manual Note the Input and Output Line Standards must be correctly set before doing this Line Standard Timing Information Standa...

Page 21: ...tem delay is 56 6 99 24 185 clocks 2 4916µs the BYPass card that replaces a non fitted option card incurs no clocks This minimum delay will of course only be achieved if all the input sources are timed appropriately As shown on the previous page sources can arrive over 47 to 79 lines depending on line standard earlier than required and still be synchronised correctly If a source arrives outside th...

Page 22: ...d directly to the switcher mainframe or via a network hub If connecting directly use a cross wired swap Ethernet cable to connect a computer network card to the 10 Base T connector on the rear of the switcher mainframe If connecting via network hub use a standard pin to pin Ethernet cable from the hub to the switcher mainframe 10 Base T connector GVG 100 This editor protocol allows control from an...

Page 23: ...rom the Editor controls the switcher s PVW 1 bus Controlling AUX 1 from the Editor controls the switcher s PVW 2 bus Controlling AUX busses 2 to 9 from the Editor controls the switcher s AUX 1 to 4 busses When setting areas of the switcher to Learn Recall Transfer DMEMs or run Timelines the protocol s BKGD area will drive the switcher s SOURCES DMEM Timeline Enable and the protocol s MISC area wil...

Page 24: ...or editors such as the Sony BVE 9000 series that use the PVW bus for the Edit Preview Bus this will not be the case SONY DVS Learn and Recall of DMEMs E Files to and from the hard disk in the switcher is supported as is the transfer of DMEMs E Files to and from the editor s EDL There are three variants of the Sony DVS Protocol They are identical except for the way that Aux and Preview busses are a...

Page 25: ...9 Alias of 82 52 PST OUT Crosspoint 57 58 3A Alias of 83 53 EFF 1 PVW OUT Crosspoint 58 59 3B Alias of 84 54 EFF 2 PVW OUT Crosspoint 59 60 3C Alias of 90 5A Still 1 Crosspoint 60 61 3D Alias of 91 5B Still 2 Crosspoint 61 62 3E Alias of 92 5C Still 3 Crosspoint 62 63 3F Alias of 93 5D Still 4 Crosspoint 63 64 40 Background OFF M E bus only OFF 65 41 Black all but HD AUX busses BLACK 66 42 Matte a...

Page 26: ...he start of the edit field by field You should get two fields one frame of the new source without the key then the key should appear on the third field of the edit interval Obviously this assumes that the recorder is correctly timed However if you use a tape with burnt in timecode you should be able to prove the switcher timing regardless of the recorder s timing and you should also be able to che...

Page 27: ...Type in the new value required 8 Press RET to exit the screen saving the value F8 EXIT leaves the screen but does NOT save the value 9 Press RET three more times to go back to the main screen The new value required should be determined by the Key Cut On test as described above but these are values we have found to be suitable in our testing with Sony BVS DVS protocol 02 to 05 inclusive with GVG 40...

Page 28: ...and locks the switcher s timeline to timecode it requests from the VTR In this case simply plug a normal pin to pin 9 pin cable between the designated port on the switcher and the remote port of the VTR 2 Alternatively in a system that has an editor or other controlling device connected to the VTR a special sniffer arrangement is inserted into the control cable between the editor and the VTR This ...

Page 29: ...mera This is a proprietary protocol for use with virtual studio software Button Bus The address code of the pressed control panel button is sent from the applicable port B Bus Multi Ctl Allows one control panel to control two mainframes in parallel i e a SD HD system P Bus Allows up to 32 RS 485 devices to be strung off a port and triggered independently Router Protocols Allows a variety of third ...

Page 30: ...Quad DSK The Inputs The general purpose inputs eight or sixteen are user programmable in the Configure User GPI menu Systems without the Quad DSK option have eight inputs and systems with Quad DSK have sixteen inputs Each input may be independently set to trigger a function when an edge or level is applied to the input connector pin The available functions depend on the type of control panel being...

Page 31: ... Tally The use of a particular bus may be tallied Trans Running The transitions Fade to Black Program Preset DSK or M E are tallied If the Quad DSK option is fitted the four external DSK transitions may be tallied T L Running A particular timeline may be tallied including those of an external DSK where fitted Also a Tally may be generated if any timeline is running T L User Bits Six flag bits are ...

Page 32: ... used to set the parameters The leftmost one steps through the GPIs the third from left selects the edge or level and the rightmost sets the value Value only applies to functions with DMEMs and is the number of the required DMEM The second from left rotary control allocates the function to the GPI When it is rotated the menu screen changes to that on the right This menu displays all the available ...

Page 33: ...the parameters Conditions The leftmost control GPO selects the GPO the next one GPO Class selects the occurrence group and GPO Mode selects the actual occurrence If T L User Bits is set as the GPO Class the rotary control T L User Bits selects the actual bit 1 to 6 to be flagged The rotary control Pulse Width determines the time that the output relay is activated Active State The active state of t...

Page 34: ...Condition When there are two or three conditions this button is used to step through them The active one has green text whereas the other s have white F3R Remove Condition This button removes the currently active condition and renumbers the others if neccessary Each condition is programmed independently of the others Select the condition with F1R and use the rotary controls as detailed previously ...

Page 35: ...ition Running Fade to Black Program Preset DSK Mixer Effects Ext DSK 2 Ext DSK 3 Ext DSK 4 Ext DSK 5 Timeline Running Key 1 Key 2 M E M E Background DVE DSK P P P P Background DVE Source Setup Global Ext DSK 2 Ext DSK 3 Ext DSK 4 Ext DSK 5 Any Timeline User Bits Each of User Bits 1 to 6 may be linked to any one of the following Key 1 Key 2 M E M E Background DVE DSK P P P P Background DVE Source S...

Page 36: ...eas where DST is implemented the clock will have to be manually adjusted twice a year For more details about this menu see User Manual System Reboot If required the system can be rebooted without powering off and on To do this hold down the four FTB buttons FTB ENABLE TIME CUT AUTO at the right hand end of the control panel at the same time as the DSK Program Preset bus BLACK buttons at the left h...

Page 37: ...atte 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Cln Pgm Aux 5 Aux 6 Aux 7 Aux 8 Store 3 Store 4 Wash Panel set up The DIL switches must be set to the following positions 1 2 3 4 5 6 7 8 OFF OFF OFF ON OFF OFF OFF ON The Panel Address rotary hex switch selects which Aux output will be controlled by the panel as detailed below 1 Aux Bus 1 source selection 5 Aux Bus 5 source selection 2 Au...

Page 38: ... low byte Where there is only one rotary switch the high byte bits 4 5 is set by switches 3 4 of the DIP switch The high byte should be set for the address range 10H to 1FH this is position 1 for the rotary control or DIP 3 4 up The other rotary switch then sets the address within this range where addresses 0 to 7 select Aux outputs 1 to 8 respectively and address 8 allows the panel to control all...

Page 39: ...Each panel is connected to a switcher serial port using a standard RS 422 RS485 cable and the protocol for that port is set to Aux Ctrl Probel or Aux Ctrl Quartz as appropriate 3 More than one panel connected to one switcher port Up to eight panels can be connected to one switcher serial port to give independent control of all available Aux O Ps whilst only using one switcher port The selected por...

Page 40: ...ype Female Connector To Extender Wiring of pins between Connectors 9 pin D type Male Connector To control Panel Description Pin 1 Pin 1 GND Pin 2 R Pin 2 TX Pin 3 Pin 3 RX Pin 4 Pin 4 Pin 5 Pin 5 Pin 6 Pin 6 Pin 7 R Pin 7 TX Pin 8 Pin 8 RX Pin 9 Pin 9 GND Both diodes are 1N4148 and both resistors are 100 ohm The resistors are only fitted to the master diode buffer ...

Page 41: ... extender The extender connects to any one of the switcher mainframe serial ports The Switcher The protocol of the switcher port must be set to Aux Ctrl Probel or Aux Ctrl Quartz as appropriate in the Config System Port Protocols menu The Panels The panels should be set up as detailed in previous pages Interconnect Diagram If using less than the maximum eight panels ensure that the Master Diode Bu...

Page 42: ...ard wiring for a controlled device which is the configuration used for all the editor interfaces currently supported In most cases only a pin to pin cable is required to connect these sockets to an external editor If the port should ever be configured as a controlling device simply exchange the words Transmit and Receive to arrive at the correct wiring Mainframe RS 232 Connector Pinout 9 way femal...

Page 43: ...2 GPI 7 13 n c 13 n c 13 GPI Common 14 GPO 1b 14 GPO 13b 14 GPO 25b 15 GPO 2b 15 GPO 14b 15 GPO 26b 16 GPO 3b 16 GPO 15b 16 GPO 27b 17 GPO 4b 17 GPO 16b 17 GPO 28b 18 GPO 5b 18 GPO 17b 18 GPO 29b 19 GPO 6b 19 GPO 18b 19 GPO 30b 20 GPO 7b 20 GPO 19b 20 GPO 31b 21 GPO 8b 21 GPO 20b 21 GPO 32b 22 GPO 9b 22 GPO 21b 22 GPI 2 23 GPO 10b 23 GPO 22b 23 GPI 4 24 GPO 11b 24 GPO 23b 24 GPI 6 25 GPO 12b 25 GP...

Page 44: ...ue Black Pin 6 Pin 7 LCD_LCDS0 LCD_LVDS1 LCD_LVDS2 LCD_LVDSCLK Pin 3 Pin 4 Pair 2 Red Black Pin 8 Pin 9 LCD_LVDS2 LCD_LVDSCLK LCD_LVDS0 LCD_LVDS1 Pin 6 Pin 7 Pair 3 White Black Pin 11 Pin 12 LCD_LVDS0 LCD_LVDS1 LCD_LVDS2 LCD_LVDSCLK Pin 8 Pin 9 Pair 4 Brown Black Pin 13 Pin 14 LCD_LVDS2 LCD_LVDSCLK GND GND Pin 11 Pin 12 Pair 5 Yellow Black Pin 1 Pin 2 GND GND GND GND Pin 13 Pin 14 Pair 6 Green Bla...

Page 45: ...16 HW_RESET CPUD8 Pin 17 Red Brown Pin 17 CPU8 CPUD5 Pin 18 Green Pin 18 CPU5 CPUD2 Pin 19 Blue Pin 19 CPU2 FROM_TOUCH Pin 20 Yellow Pin 20 TOUCH_TX V3V3_PSU Pin 21 Brown Pin 21 V3V3_PSU GND Pin 22 Black Pin 22 GND 12V_PSU Pin 23 White Pin 23 P12V_PSU GND Pin 24 Violet Pin 24 GND_LCD GND Pin 25 Turquoise Pin 25 GND_LCD 12V_PSU Pin 26 Pink Pin 26 P12V_LCD 12V_PSU Pin 27 Yellow Brown Pin 27 P12V_LCD...

Page 46: ...puts an offset may be set to move the outputs being used with the switcher to a contiguous block of 20 starting at a number other than 1 This offset facility does not apply with the Snell Wilcox HD1132 Router Setting the System for a Router The router is controlled from the switcher via a RS422 link The router control protocol has to be allocated to a switcher comm port in the Configure Port Proto...

Page 47: ...1 Timed Aux Outputs Untimed Aux Outputs Pgm 1 2 1 2 1 2 1 2 Clean Pvw 1 Pvw 2 Y Pb Pr The above diagram shows a 64 input router Connections between any router and the switcher are the same as in the above diagram except for the return signals These signals Program Clean Preview 1 and Preview 2 are fed back into the router so as be available for the Aux outputs If this is not required the returns n...

Page 48: ...www snellwilcox com Page HD1012 Installation Manual V3 Issue 1 Rev 1 S W Production Post Production 40 DELIBERATELY BLANK ...

Page 49: ...www snellwilcox com S W Production Post Production HD1012 Installation Manual V3 Issue 1 Rev 1 Page 41 SECTION B SPECIFICATIONS ...

Page 50: ...MPTE 274M 14 as per RP211 1080p 24Hz sF ANSI SMPTE 274M 15 as per RP211 1080p 23 976Hz sF ANSI SMPTE 274M 16 as per RP211 1080p 30Hz ANSI SMPTE 274M 7 292M G 1080p 29 97Hz ANSI SMPTE 274M 8 292M H 1080p 25Hz ANSI SMPTE 274M 9 292M I 1080p 24Hz ANSI SMPTE 274M 10 292M J 1080p 23 976Hz ANSI SMPTE 274M 11 292M K 720p 60Hz ANSI SMPTE 296M 1 292M L 720p 59 94Hz ANSI SMPTE 296M 2 292M M INTERNAL PROCESS...

Page 51: ...nce Input On line Switchable between From any HD SDI Video Input Analogue HD sync on 2 x BNC loop through Analogue SD sync same connection as HD sync INPUT FORMATS LEVELS HD SDI Input Format 1 485 Gbits second serial digital interface as per ANSI SMPTE 292M Analogue HD Reference 300mV tri level sync Analogue SD Reference 300mV sync with optional 300mV pk pk burst 6dB Impedance 75 ohms except refer...

Page 52: ...NC on line switchable between 8 10 bits 1 off on line switchable YPbPr RGB on 3 x BNC Preview 2 Outputs 2 off HD SDI each on 1 x BNC on line switchable between 8 10 bits Reference Output 1 off Analogue sync on 1 x BNC OUTPUT FORMATS LEVELS HD SDI Output Format 1 485 Gbits second serial digital interface as per ANSI SMPTE 292M Analogue Y R G B 700mV black white with 300mV tri level sync Analogue Pb...

Page 53: ... x RJ45 connector Interfaces to external equipment e g router editor DVE audio mixer etc 4 off freely assignable freely configurable RS 422 each on 1 x 9 way female D type Protocols currently implemented are HD1132 Router and GVG 100 110 all manufacturer s trademarks respected GPI inputs 8 TTL level inputs on x 25 way female D type Tally outputs 32 isolated contact closures on 2 x 25 way female D ...

Page 54: ... pin mini DIN PS 2 style socket External Pointing Device RS 232 DTE on 1 x 9 way male D type Driver software not currently implemented External Display SVGA compatible on 1 x 15 way female sub D type Signal freq 39 06kHz Horizontal 62 5Hz Vertical Diagnostics Early Mark 2 Panels RS 232 DTE on 1 x 9 way male D type Diagnostics Later Mark 2 Panels RS 232 DCE on 1 x 9 way female D type CONTROL INTERF...

Page 55: ... brackets 24 inches nominal 610 mm including connectors Weight 48kg approx with all options fitted not including the HD1132 mainframe which adds a further 17kg Environmental 5 to 35 C non condensing PHYSICAL CP1512 Control Panel Size Overall Tub Suggested Cutout Depth Clearance 871mm x 537mm not including display overhang 819mm x 511 5mm 822mm x 517mm 200mm Weight To be advised Environmental 5 to ...

Page 56: ... fully independent hot swappable PSU modules with separate mains power feeds via 2 x IEC socket Control Panel Two fully independent PSU modules with separate mains power feeds via 2 x IEC socket POWER REQUIREMENTS Voltage 115V 230V 50 60Hz Mainframe Power Less than 1000 Watts with all options fitted Control Panel Power Less than 50 Watts ...

Page 57: ...www snellwilcox com S W Production Post Production END OF MANUAL ...

Reviews: