58
-
1) Please click on the [Detailed Setting] button in the [Point Table] tab.
2) Please confirmation
or change of
[Feel length multiplication (STM) (Multiplier)].
3) Click on the "OK" button.
4) Target position input range varies depending on the set value of
[Feel length multiplication (STM)
(Multiplier)].
Feed length multiplication (STM) (Multiplier)
(Feed unit [
μ
m])
Target position input range
[mm]
1
-999.999 to +999.999
10
-9999.99 to +9999.99
100
-99999.9 to +99999.9
1000
-999999 to +999999
For actuators with a stroke less than 1000mm, set
parameter
“PE02 (Feed function selection)” to 0000 and the
"Feed length multiplication (STM) (Multiplier)" value to x1.
For actuators with a stroke more than 1000mm, set
parameter
“PE02 (Feed function selection)” to 0001 and the
"Feed length multiplication (STM) (Multiplier)" value to x10.
1)
2)
4)
3)