48
-
(3) Example of Signal Allocation using the setup software
When changing pins CN1-7 from Reverse rotation start (ST2) to point table no./program no. selection 3 (DI2):
①
Change PD12 from 0808 to 2E08 in the I/O tab.
②
Click on the "Single Axis Write" button.
③
Cycle the power off, and then on for the parameters to be enabled.
* Complete pin CN1-7 allocation separately.
* See
“
LEC
SA Operation Manual”,section 4.4.2 for details on allocation of input signals to pins CN1-3 - CN1-8
* See
“
LEC
SA Operation Manual”,section 4.4.2 for details on allocation of input signals to pins CN1-23 and CN1-25
* See
“
LEC
SA Operation Manual”,section 4.4.2 for details on allocation of output signals to pins CN1-9 and CN1-12
Schematics showing typical 3 point positioning
0808
↓
2E08
②
①