-81-
No. JXC
※
-OMY0008
Unsuitable
specification
Check if the controller’s
specifications are appropriate,
the power supply is suitable
and the controller is compatible
with the actuator.
Take appropriate measures according to
this manual.
→
3. Specifications (P.13)
Voltage
drop
Check for a temporary voltage
drop in the power supply?
(If there is a temporary voltage
drop in the power supply, the
EMG terminal of CN1 power
connector will turn OFF so the
actuator will stop. However, this
stop will be released when the
voltage recovers.)
There is a possibility of a momentary
voltage drop because the capacity of
the power supply is insufficient, or if the
power supply is "inrush-current control"
type.
If necessary, replace the power supply.
→
3. Specifications (P.13)
7
Speed not