-74-
No. JXC
※
-OMY0008
18.3 Mounting
Warning
(1) The controller and its peripheral devices should be installed on a fire-proof material.
Direct installation on or near a flammable material may cause fire.
(2) Do not install this product in a location subject to vibration and impact.
A failure and malfunction can result.
(3) Take measures so that the operating temperature of this controller and its peripheral devices
are within the range of the specifications.
Also, this controller should be installed with at least 50mm space between each side of it and
other structures or components.
It may cause a malfunction of the controller and its peripheral devices and a fire.
(4) Do not mount the controller and its peripheral devices near a large electromagnetic contactor
or no-fuse breaker which generates vibration on the same panel. Mount them on different
panels, or keep the controller and its peripheral devices away from such a vibration source.
(5) The controller and its peripheral devices should be installed on a flat surface.
If the mounting surface is distorted or not flat, excessive force may be applied to the housing, etc.
causing malfunction.
18.4 Wiring
Warning
(1) Do not damage the cable or apply a heavy object or pinch the cable. Avoid repeatedly
bending or stretching the cable.
It may cause an electric shock, fire, or breaking of wire.
(2) Wire correctly.
Incorrect wiring could damage the controller or its peripheral devices depending on the seriousness.
(3) Do not perform wiring while the power is on.
It can damage the controller or its peripheral devices could be damaged, causing malfunction.
(4) Do not carry this product by holding its cables.
It may cause an injury or damage to the product.
(5) Do not route wires or cables together with power or high voltage cables.
The wires to the controller or its peripheral devices can be interrupted with noise or induced surge
voltage from power lines or high-voltage lines, causing malfunction.
Route the wires of the product separately from power or high voltage cables.
(6) Verify the insulation of wiring.
Insulation failure (interference with another circuit, poor insulation between terminals etc.) could
introduce excessive voltage or current to the controller or its peripheral devices and damage them.