-36-
No. JXC
※
-OMY0008
●Index 7024h
: Deceleration
Index
Bit
Signal name
Description
Input range
Min. unit
7024h
0-15
Deceleration
1 ~ Basic parameters
"Maximum deceleration speed" (
∗
7,
∗
11)
1 mm/s
2
●Index 7025h
: Pushing force
Index
Bit
Signal name
Description
Input range
Min. unit
7025h
0-15
Pushing force
(
∗
7,
∗
11)
1%
●Index 7026h
: Trigger LV
Index
Bit
Signal name
Description
Input range
Min. unit
7026h
0-15
Trigger LV
(
∗
7,
∗
11)
1%
●Index 7027h
: Pushing speed
Index
Bit
Signal name
Description
Input range
Min. unit
7027h
0-15
Pushing speed
(
∗
7,
∗
11)
1 mm/s
●Index 7028h
: Moving force
Index
Bit
Signal name
Description
Input range
Min. unit
7028h
0-15
Moving force
(
∗
7,
∗
11)
1%
●Index 7029h
: AREA 1
Index
Bit
Signal name
Description
Input range
Min. unit
7029h
0-31
AREA1
Basic parameter
"Stroke (-)" - "Stroke (+)" (
∗
5,
∗
7,
∗
11)
0.01 mm
●Index 702Ah
: AREA 2
Index
Bit
Signal name
Description
Input range
Min. unit
702Ah
0-31
AREA2
Basic parameter
"Stroke (-)" - "Stroke (+)" (
∗
5,
∗
7,
∗
11)
0.01 mm
●Index 702Bh
: In-Position
Index
Bit
Signal name
Description
Input range
Min. unit
702Bh
0-31
In-Position
(
∗
7,
∗
11)
0.01 mm
∗
5 Please refer to
20. Handling of sent/received data (P.82)
for handling of the data.
∗
7 Change the numerical data input flag and the numerical data only when the start flag is OFF. If the
numerical data input flag or the numerical data are changed when the start flag is ON, it may lead to
unexpected operation.
∗
11 The actuator model determines the limit for the input values. Please refer to the manual of the
actuator for more details.