44
2)IZTC41
Note 52) Refer to [4-4. Controller setting] or [4-5-2. Alarms for IZT41, IZT42] for details of frequency.
13
14
1
10
9
2
4
7
8
3
5
6
11
12
Table12. Name of parts
No.
Name
Panel
indication
Type
Description
1
CH display
CH
□
LED
(Green)
LED of high voltage power supply module connected to the controller is ON (green),
LED flashes (green) during frequency selection, offset voltage adjustment,
balance control selection, maintenance detection level selection,
Turned off when the high voltage power supply module is not connected.
2
Frequency display
Hz
LED
(Green)
ON during operation,LED flashes (green) during frequency selection,
offset voltage adjustment,balance control selection,
maintenance detection level selection,
key lock setting and each abnormality. Note 52)
3
Ion balance display
ION BALANCE
LED
(Green/ Orange)
LED (green) is ON during operation or output signal over current.
LED (green) flashes during offset voltage adjustment.
LED is OFF flashes (red) when CPU abnormality (controller/ high voltage power supply
module),
power supply abnormality, communication error, cooling fan motor failure,
module inconsistency, or CH duplication exists.
LED (orange) flashes when ion balance is maximum or minimum during offset
adjustment.
Turned off when the high voltage power supply module is not connected
4
Ion emission/
high voltage error display
ION/HV
LED
(Green / Red)
Green LED is ON during static neutralization.
Red LED is ON when high voltage abnormality exists.
LED flashes (red) when CPU abnormality (controller/ high voltage power supply module),
power supply abnormality, communication error, cooling fan motor failure,
module inconsistency, or CH duplication exists.
Turned odd when the high voltage power supply module is not connected
5
Indication of connected mode
DAC/AC
LED
(Green /Blue)
LED is ON (green) when the high voltage power supply module IZTP41 is connected.
LED is ON (blue) when the high voltage power supply module IZTP42 is connected.
OFF when CPU abnormality (controller) or CH duplication exists,
or high voltage power supply module is not connected.
6
Maintenance display
NDL
LED
(Green)
LED (green) is ON when emitter contamination is detected.
LED (green) flashes when the maintenance detection level is set.
Turned off when the high voltage power supply module is not connected
7
Key-lock display
KEY
LED
(Green)
Key lock ON : ON (green)
Key lock OFF : OFF
Turned off when the high voltage power supply module is not connected.
8
Sensor LED
SNSR
LED
(Green)
Auto balance function ON : ON (green)
Auto balance function OFF : OFF
OFF when CPU abnormality (controller) exists or high voltage power supply module
is not connected.
9
▼
button
-
Press button
Decrease the set value.
10 S button
-
Press button
Change the mode and set a set value.
11
▲
button
-
Press button
Increase the set value.
12 Reset button
-
Press button
Return the setting values of each mode to the default condition.
13 Power supply connector
-
Connector
Equipped with ionizer power supply and grounding.
14
High voltage power supply
module connector
-
D-sub
connector
(socket)
Connect high voltage power supply module or separate cable.