28
Ⅲ.
When the high voltage power supply module is added directly
a. Removal of the fixing bracket
·
Remove the fixing bracket from the DIN rail mounting bracket at the adjoining faces indicated at
location E.
b. Mounting of DIN rail mounting bracket
·
Fix the controller and high voltage power supply module to the DIN rail mounting bracket using M4
screws .
Tightening Torque: 1.30 to 1.50 Nm
c. Connect the controller and high voltage power supply module
·
Connect the D-sub connector in location C and fix the controller and high voltage module
together using M4x30 screws (2 pcs. included as an accessory).
Tightening Torque: 0.22 to 0.24 Nm
C : D-sub connector
IZT40-B1
DIN rail mounting bracket
for controller
Fix with M4 screws
(Included)
Addition of module
M4x30
(Included)
IZT40-B2
High voltage power
supply module
DIN rail mounting bracket
for IZTP40/IZTP41
Fix with M4
screws
(Included)
IZT40-B2
High voltage power
supply module
DIN rail mounting bracket
for IZTP40/IZTP41
Fix with M4
screws
(Included)
E. Remove the fixing bracket
Summary of Contents for IZT40 Series
Page 1: ...Document No IZ OMT0049 B PRODUCT NAME Ionizer MODEL Series IZT40 41 42series...
Page 73: ...High voltage power supply module IZTP40 IZTP41 When DIN rail mounting bracket IZT40 B2 is used...
Page 74: ...High voltage power supply module IZTP42 When DIN rail mounting bracket IZT40 B3 is used...