3)When error occurs
Note 12) It takes 3 seconds to operate after the power is on.
Note 13) Abnormality can be released by the ion generation stop signal. Release the error after recovery.
Note 14) Frequency of the high voltage power supply module with a problem is displayed by flashing error code.
Refer to [4-5-1. Alarms for IZT40]. High voltage power supply module without problem indicates normal status.
Note 15) All ION/ HV of CH1 to 4 flash (red).
Note 16) All connected high voltage power supply module ION/HV flash (red).
Note 17) High voltage power supply module ION/HV with problem flashes (red).
Note 18) High voltage power supply module ION/HV with problem turns on (red).
Note 19) The screen at the time of problem occurring holds the status before the problem.
Note 20) All the selected bars (high voltage power supply module) stop ion generation.
Note 21) Bar with a problem (high voltage power supply module) stops ion generation.
Key-lock (green)
KEY
Ion generating status
D
is
p
la
y
CH display
Selected CH to display
CH
CH display
CH which display is not
selected
CH display
High voltage power supply
module disconnected
Ions are generated (green)
ION/HV
Incorrect high voltage (red)
Frequency
Hz
In
p
u
t
Power 24 VDC
―
Controller button
▲
/
▼
/ S button
―
Incorrect high voltage
Error code
:
E3
Communication error
Error code
:
E4
Display
Status
CPU failure (controller)
Error code
:
E0
Power supply failure
Error code
:
E1
CPU failure
(High voltage power supply module)
Error code
:
E2
ON
OFF
ON
OFF
ON
OFF
ON
OFF
点灯
消灯
ON
OFF
ON
OFF
点灯
消灯
ON
OFF
Error
Error
Error
Note 19)
Note 19)
Note 19)
Error
Note 19)
ON
OFF
ON
OFF
Power
OFF
Power
ON
Power
OFF
Power
ON
Power
OFF
Power
ON
ON
OFF
1Hz
Note 14)
1Hz
Note14)
1Hz
Note 14)
1Hz
Note 14)
1Hz
Note 15)
1Hz
Note 16)
1Hz
Note 17)
Note 18)
Error
Note 19)
Power
OFF
Power
ON
1Hz
Note 14)
1Hz
Note 17)
Note 12)
Note 12)
Note 12)
Note 12)
ON
OFF
点灯
消灯
1Hz
1Hz
1Hz
Note 20)
Note 20)
Note 21)
Note 21)
Note 21)
Note 13)
Note 13)
1Hz
1Hz
Generate
Stop
Key-lock (green)
KEY
Ion generating status
D
is
p
la
y
CH display
Selected CH to display
CH
CH display
CH which display is not
selected
CH display
High voltage power supply
module disconnected
Ions are generated (green)
ION/HV
Incorrect high voltage (red)
Frequency
Hz
In
p
u
t
Power 24 VDC
―
Controller button
▲
/
▼
/ S button
―
Fan motor failure
Error code
:
E5
Inconsistent module
Error code
:
E6
Duplication of CH
Error code
:
E7
High voltage power supply module
not connected
Error code
:
--
Display
Status
ON
OFF
ON
OFF
ON
OFF
ON
OFF
点灯
消灯
ON
OFF
ON
OFF
点灯
消灯
点灯
消灯
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Error
Note 19)
Power
OFF
Power
ON
Error
Power
OFF
Power
ON
Error
Note 19)
Note 19)
1Hz
Note 14)
1Hz
Note 14)
1Hz
Note 14)
1Hz
Note 17)
1Hz
Note 17)
1Hz
Note 17)
Error
Power
OFF
Power
ON
1Hz
Note 14)
Note 12)
Note 12)
Note 12)
Note 19)
Note 13)
1Hz
1Hz
1Hz
Note 21)
Note 21)
Note 21)
Generate
Stop
Summary of Contents for IZT40 Series
Page 1: ...Document No IZ OMT0049 B PRODUCT NAME Ionizer MODEL Series IZT40 41 42series...
Page 73: ...High voltage power supply module IZTP40 IZTP41 When DIN rail mounting bracket IZT40 B2 is used...
Page 74: ...High voltage power supply module IZTP42 When DIN rail mounting bracket IZT40 B3 is used...