23
2) Intermediate bracket (for bar lengths of 820mm or more)
·
Match the groove of the bar and protrusion of the intermediate
bracket, and slide the bracket from the end of the bar.
·
Intermediate brackets should be mounted at the same intervals.
3) Installation of the bar
·
Fix the bracket to the specified position using M5 screws.
·
Refer to "6. Dimensions" section for details.
(The screws should be prepared by the user).
4)Mounting angle adjustment
·
Adjust the mounting angle of the bar for effective neutralization, and fix the product with the rotating set
screw (M4 ) at each bracket.
Tightening Torque
IZT40-BE1 (End bracket 1) : 0.72 to 0.76Nm
IZT40-BE2 (End bracket 2) : 0.72 to 0.76Nm
IZT40-BM1 (Intermediate bracket 1) : 0.72 to 0.76Nm
IZT40-BM2 (Intermediate bracket 2) : 0.47 to 0.49Nm
3-1-6. Connecting the controller and high voltage power supply module
·
Remove the protection film on the controller before use.
·
The product is used by connecting the controller and high voltage power supply module. They can be
connected either directly or separately. For separate connection, an optional separate cable is required.
·
Mount a dust cover on the D-sub connector when not using the directly mounted high voltage power supply
module.
IZT40-BM1
Intermediate bracket 1
IZT40-BM2
Intermediate bracket 2
M5 screw
IZTB40/IZTB42
Bar
M5 screw
90
o
IZT40-BE1
End bracket 1
IZT40-BM1
Intermediate bracket 1
IZT40-BE2
End bracket 2
IZT40-BM2
Intermediate bracket 2
M4 screw
M4
screw
90
o
15
o
15
o