79
9. Maintenance
·
If the ionizer is used for an extended period of time, contamination such as dust will stick to the emitters,
reducing the static neutralization performance.
·
The maintenance detection function is available for the IZT41 and IZT42. When the emitter contamination is
detected, clean the emitter.
·
In cases where the maintenance detection function is not used on the IZS41 or IZS42 or IZT40 is used,
perform neutralizing performance test and set a maintenance cycle for periodic cleaning.
·
Emitter contamination level is different depending on the installation environment and supply pressure.
·
If the maintenance signal is output upon completion of cleaning the emitter, it may not have been cleaned
sufficiently or it may be worn or damaged. If the emitters are worn out or damaged, replace the emitter
cartridge.
·
If the emitter is worn out or damaged, the static electricity elimination performance will decrease.
Cleaning procedure of emitter
·
It is highly recommended that the emitter cleaning kit (IZS30-M2) is used to clean the emitter needles.
a. Before cleaning the emitters, shutoff the power and air supply.
b. The emitters may be cleaned with the emitter cartridges mounted to the bar or with the cartridges
removed from the bar.
Refer to "Removal procedure of emitter cartridge" shown below for instructions on how to remove the
cartridges.
c. The emitter cleaning kit (IZS30-M2) has felt at one end of the tool and rubber-bonded whetstone at the
other end of the tool.
Emitter cleaning kit
(IZS30-M2)
Removal procedure of emitter cartridge
(1) Rotate 90 degree
(2) Pull out
Rubber-bonded whetstone
(Green)
·
A high voltage generating circuit is mounted onto this product. Verify that the power supply is OFF when
performing maintenance.
·
When compressed air is supplied to the product, shutoff the supply before performing any maintenance
operation.
·
Never disassemble or modify the product, as this can cause loss of product functionality and a risk of
electric shock and earth leakage.
·
Do not touch the end of the emitters. They have a sharp end and touching them directly with your fingers
may cause injury.
·
Only people who have sufficient knowledge and experience are allowed to clean the emitters.
Warning