48
4-4. Controller setting
4-4-1. Operation overview
1) Setting IZT40
(Default condition)
Frequency setting : 30Hz
Key lock : OFF
[Channel selection mode]
Select the CH number for setting and display. When multiple bars (high voltage power supply modules) are
connected, switch the CH for setting and display. Refer to 4-4-2. Channel selection mode for details.
Note 53)
[Frequency set
mode]
Set the ion generation
frequency of the bar
selected by "Channel
selection
mode”.
Refer to 4-4-3.
Frequency set mode
for details.
Note 53)
[Key-lock setting
mode]
Perform a key-lock
setting.
Refer to 4-4-7.Key-lock
set mode for details.
[Offset voltage
adjustment mode]
Adjust the offset
voltage of the bar
selected by ”CH
selection mode".
Refer to "4-4-4.
Adjustment of Offset
Voltage" for details.
Note 53)
[Channel selection mode]
Press S button once
Press S button for 3 sec. or longer
Press S button once
Press S button once
Press S button once
Immediately after power is supplied
Note 53) In Channel selection mode, frequency set mode, or offset voltage adjustment mode, the selected bar
(high voltage power supply module) moves on to the ion generation stop mode by pressing
▼ and ▲
button
simultaneously for 2 s or longer and stops the ion generation. (Operation is not possible while the key lock is
ON). To release, press the S button once or turn the power off and on again. Refer to [ 4-4-8. ion generation
stop mode] for further details