-99-
No.EX##-OMV0017-D
- Wireless Remote unit (manifold type) (EX600-WSV#) setting parameters
Classificat
ion
Parameter name
Set value
Initial
value
Setting
when
power is off
Note
Remote
setting
a)
HOLD/CLR
(unit)
CLEAR / HOLD / Software Control
CLEAR
Available
Setting the output operation when the
fieldbus communication is
disconnected.
b) Input size
0 to 128 points (0 to 16 bytes)
Increase and decrease by 16 points
(2 bytes).
128 points
/ 16 byte
Available
c)
Output size
(includes
valves)
0 to 128 points (0 to 16 bytes)
Increase and decrease by 16 points
(2 bytes).
128 points
/ 16 byte
Available
d)
in which
includes a
valve density
of
0 to 32 points (0 to 4 bytes)
Increase and decrease by 8 points
(1 byte).
32 points /
4 byte
Available
The valve manifold output points are
included in the module output points.
The number of effective points are
limited to within the setting range of
the module output points.
e)
Wireless
signal
Active / Idle
Active
Available
If set to "Idle", the wireless
communication is disconnected.
f)
AD refresh
time (sec)
0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 / 30 / 60
s
1 s
Available
Set the sampling frequency of the
analog input equipment.
g)
Unit address
order
Mode 1 / Mode 2
Mode 1
Available
Mode 1:
Allocation to the right from the end
plate.
Mode 2:
Allocation to the left from the wireless
unit.
Pairing
setting
a) Pairing
Normal / pairing modes
Normal
mode
Available
Normal mode:
Wireless Remote cannot be registered
(Communication with the registered
Remote will be established).
Pairing mode:
Wireless Remote can be registered.
- Parameters in common with Wireless Base units and Wireless Remote units
Classification Parameter name
Set value
Initial value
Setting when
power is off
Note
Information
TAG
Max. 15 characters
Part No
(EX600-WEN#)
(EX600-WPN#)
(EX600-WSV#)
(EXW1-BMJA#)
(EXW1-
RDXNE4#)
(EXW1-
RDYNE4#)
(EXW1-
RDM#E3)
Available
Characters which can be input
are half-width characters
(alphabet, numbers, symbols)
representable in ASCII code.
Half-width katakana cannot be
entered.