-57-
No.EX##-OMV0017-D
2) Valve
- Description display (valve)
Display
Description
Part No
Wireless Base / Remote product number.
Unit No.
Mapped position for the valve. Displays the mapped position of the selected digital input
unit.
*
Refer to "5.3.2 Parameters", "Unit address order" for details on mapped position.
Unit status
Displays the mapped diagnostic data bits for the selected valve.
* Content of diagnostics
N: Normal Error is not detected
O: Bit Open Load is not connected (disabled at initial status)
S: Bit Short Short circuit of the load output is detected
L: Limit Over Contact operation exceeded the limit (disabled at initial status)
P: Power Short Short circuit of the load power supply is detected
HOLD / CLR / SET
Output operation when communication of the valve is disconnected.
In / Out offset
Displays the start position of the address to which the selected unit is mapped on the I/O
map.
In / Out size
Valve input / output size. Input size is always 0 bytes.
Input data
"--" is displayed for the valve (setting is only applicable to units with inputs).
Output data
Displays the data which is sent from the valve.
Content of
diagnostic
Address in the unit
Example: byte 0, bit 4