Preface.

This manual describes the mechanical and electrical installation of the smart Wallbox. The working 
steps described in this manual must only be carried out by qualified specialist personnel (mechanical 
installation) and qualified specialist electrical contractors (electrical installation), who, on the basis of 
their specialist training, knowledge and experience as well as their knowledge of the relevant regula-
tions, can assess and carry out the working steps described in this installation manual and recognize 
potential hazards.

The model variants of the smart Wallbox can be identified by the product labels on the wallbox. These 
labels state the smart product identification number (exterior underside) as well as the ABL model num-
ber (interior electronic components cover), but are identical regarding technical specifications. Always 
make sure before installation that your model variant is the one described in this installation manual!

The following wallbox model variant is the subject of this manual:

smart product identification number

ABL model number

A0009069106

3W72S2

About this manual.

This manual is included with the smart Wallbox and documents the steps and settings required for in-
stalling the wallbox, taking it into operation as well as for resolving malfunctions during operation. For 
quick and easy reference, certain sections of this manual are specially formatted. 

 

> Descriptions listing equally valid options (as is the case here) are indicated by bullet points.

 

> Descriptions that describe performing a function are shown in the form of numerical lists indicating 

the order of the individual working steps.

Please make sure you read this manual carefully and ensure in particular that you follow all safety 
notices given in this manual.

All measurements in this manual are in millimeters. Where necessary, the scale is indicated for differ-
ent illustrations.

Please note that all technical details, specifications and design characteristics of the product may be 
changed without prior notice.

Safety notices in this manual. 

In particular, the warnings and safety measures in this manual that are marked as follows must be ad-
hered to. The symbols carry the following meanings:

DANGER! 

 

Sections marked with this symbol draw attention to electrical voltages that represent a dan-
ger to life and limb: Actions contrary to these safety notices may lead to severe injury and 
death. Actions marked with this symbol must not be carried out under any circumstances.

01

Summary of Contents for 3W72S2

Page 1: ...smart Wallbox Installation manual for specialist electrical contractors...

Page 2: ...r local smart technical support This manual in its entirety or in parts must not be reproduced stored electronically or otherwise transmitted electronically electrically mechanically optically chemica...

Page 3: ...on site 7 Requirements for the power supply 8 Mechanical installation of the mounting plate 12 Taking the wallbox into operation 03 14 Error detection and solutions 14 Operational disruptions and solu...

Page 4: ......

Page 5: ...s manual is included with the smart Wallbox and documents the steps and settings required for in stalling the wallbox taking it into operation as well as for resolving malfunctions during operation Fo...

Page 6: ...NING After opening the housing dangerous voltages may be present on the inside of the wallbox as well as on components you are able to touch General safety information Please pay attention to the foll...

Page 7: ...o be used by persons with limited physical sensory or mental abilities including children and or lacking knowledge unless they are supervised by someone responsible for their safety or have received i...

Page 8: ...egulations for the country in which you operate the wallbox For proper operation the power supply for the wallbox must be protected in the domestic power sup ply with suitable MCB s and RCCB To discon...

Page 9: ...any time Should a malfunction occur you can identify the cause by its specific LED error code without having to open the housing After be ing taken into operation by a specialist contractor the smart...

Page 10: ...roduct sticker Fixed charging cable according to IEC 62196 2 Type 1 ca 7 4 m charging output 7 2 kW WARNING The information and technical specifications contained in this manual relate exclusive ly to...

Page 11: ...protection from weath er related pollution Requirements for the power supply The following standards must always be considered for the electrical installation of the smart Wallbox All regulatory requi...

Page 12: ...owing link www yourwallbox de Mains_Connection_Schemes Mechanical installation of the mounting plate After determining the mounting site for the wallbox you can begin with mechanical installation For...

Page 13: ...red please remove one of the plastic tongues in tended for the power supply cable with a suit able pair of pliers a cutter or drill 83 3 Place the mounting plate on the chosen mount ing surface Use a...

Page 14: ...nal damage If possible only re move the protective film from the housing cover just before completing installation 8 Use the screwdriver to loosen the TX20 screw holding the internal electronic compon...

Page 15: ...nnected as follows Designation Wire colors Connection coding Current carrying conductor phase 1 Brown L1 Neutral Blue N Protective earth Green Yellow PE DANGER Please note that the electronic componen...

Page 16: ...ousing cover upwards so that it clicks into the housing and lock it with the triangular key supplied Taking the wallbox into operation After mechanical and electrical installation you must check the c...

Page 17: ...n the blue LED flashes every 5 seconds the green LED and the red LED go out The vehicle can now be connected for charging The charging procedure itself is described in the operating manual included PL...

Page 18: ...ermanently contact your lo cal smart technical support The wallbox has not been connected in ac cordance with the re spective type of mains power connection for the country of instal lation Check your...

Page 19: ...n LED flashes three times then the blue LED flashes once the red LED is continu ously ON Solution In both cases switch the power supply off and then back on again If the error continues to occur take...

Page 20: ...cable If the cable does not show signs of damage the vehicle must be checked Please contact a qualified specialist repairer 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Descri...

Page 21: ...llbox out of operation see Taking the product out of and back into operation on page 21 and contact your local smart technical support 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 20...

Page 22: ...voltage 4 Ground and short circuit 5 Cover or prevent access to adjacent parts under voltage Otherwise there is a risk of severe injury or even death through electric shock Two rotary encoders S1 and...

Page 23: ...be indicated by the LED display after you have switched the power supply to the wallbox back on in step 3 Error description LED status The settings could not be saved in the memory The wallbox was set...

Page 24: ...off automat ically all LEDs are illuminated 6 To terminate testing mode switch off the power supply of the wallbox via the upstream MCB s and RCCB 7 Remove the internal electronic com ponents cover S...

Page 25: ...t the operation of the wallbox It is therefore recom mended not to make any changes and to generally leave the S3 rotary encoder in the 0 position 2 0x02 3 0x03 4 0x04 5 0x05 6 0x06 7 0x07 8 0x08 9 0x...

Page 26: ...e error can still not be resolved repairs must be carried out For this purpose you must take the wallbox out of operation uninstall it and return it via smart technical support In addition to the wall...

Page 27: ...Customization internal RS485 interface no user installer access Operating temperature 30 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensation Class of protection I Ove...

Page 28: ...ions The smart Wallbox is delivered fully assembled and quality checked All dimensions as well as the mounting points are indicated in the scale drawings below Mounting plate Plan and elevation all di...

Page 29: ...lbox Appendix 25 Wallbox with fixed charging cable Plan and elevation all dimensions in mm 394 143 492 134 194 400 492 134 194 Contact chart Type 1 Type 2 Type 2 Type 1 PE N L3 PP PE L1 L2 CP CS L2 N...

Page 30: ...ehicles DIN EN 61851 1 2012 01 Conductive charging systems for electric vehicles Part 1 General re quirements E DIN EN 61851 22 2011 04 Conductive charging systems for electric vehicles Part 22 AC cha...

Page 31: ...rading names or company names marked here as such are or may be trademarks or registered trademarks of their respective owners All rights not explicitly granted here are reserved The absence of explic...

Page 32: ...nic devices are taken back by the manufacturer in order to have them properly disposed of or recycled Therefore devices marked with this symbol may not be disposed of as part of unsort ed domestic was...

Page 33: ...esia Tahiti 60 Hz 220 V L1 N x Hong Kong 50 Hz 220 380 V L1 L2 L3 N x India 50 Hz 220 380 V L1 L2 L3 N x 230 400 V 240 415 V Indonesia 50 Hz 127 220 V L1 L2 x 220 380 V L1 L2 L3 N x Israel 50 Hz 230 4...

Page 34: ...e 50 Hz 230 400 V L1 L2 L3 N x United Arab Emirates 50 Hz 220 380 V L1 L2 L3 N x 240 415 V Vietnam 50 Hz 127 220 V L1 L2 x 220 380 V L1 L2 L3 N x Region Country Local frequency Local voltage domestic...

Page 35: ...smart Wallbox 31...

Page 36: ...rt www smart com The manufacturer may have made minor technical modifications to the product after publication of this installation manual This may also have led to minor discrepancies in the appearan...

Reviews: