> The power supply for the wallbox must always be protected by its own MCB and RCCB (at least Type
A): Please always observe current national regulations regarding the selection of MCB and RCCB.
Depending on the country, an RCCB with a different tripping type (e.g. Type B) may be prescribed.
> The wallbox does not have a dedicated ON/OFF switch: If you want to take the wallbox out of opera-
tion, you must always switch the upstream domestic MCB(s) and RCCB to the 0 (OFF) position.
> Please always ensure that the installation requirements listed in this manual are complied with.
Disregard or actions to the contrary may lead to severe injury by electric shock or even death. In
addition, in case of contravention of the notices given, the proper operation of the wallbox cannot
be guaranteed.
PLEASE NOTE!
In some countries, the requirements mentioned in this manual differ from the prerequi-
sites for connecting to the local power grid. In this case, the wallbox must be connect-
ed in accordance with the respective type of mains power connection for the country of
installation. You can find an overview of country-specific mains connection schemes on
page 29 in this manual or on the
www.yourwallbox.de
website using the following link:
www.yourwallbox.de/Mains_Connection_Schemes
Mechanical installation of the mounting plate.
After determining the mounting site for the wallbox, you can begin with mechanical installation. For
installation you will need the following components:
> Power drill or cordless drill (not included)
> Drill bit Ø 10 mm, appropriate for the wall substrate (not included)
> Screwdriver with flat head (2.5 mm blade width), Phillips head (PH1) and torx head (TX40, TX25, TX20,
TX10) bits
> Mounting plate (included)
> Pliers or cutter for breaking or cutting out the cable inlet in the mounting plate (not included)
> Four 8 x 60 wafer head (TX40 bit) screws for fixing the mounting plate (included)
> Four 6 x 25 (TX25 bit) screws for fixing the wallbox housing to the mounting plate (included)
> If required: Wall plugs suitable for the mounting substrate (included: 10 x 50 nylon wall plugs)
> Spirit level if required (not included)
DANGER!
Always observe the 5 golden rules of electrical installation:
1. Cut off all voltage sources
2. Secure all cut-off devices
3. Verify absence of voltage
4. Ground and short-circuit
5. Cover or bar access to adjacent components under voltage
Always deactivate the MCB(s) and RCCB allocated to the wallbox in the domestic power sup-
ply before you begin installation. Also ensure that the MCB(s) and RCCB cannot be reacti-
vated during installation. Otherwise, there is a risk of severe injury through electric shock