smart Wallbox
Error detection and solutions
21
Position
Description
Explanation
5
Setting the maximum
charging current
8 A
6
10 A
7
13 A
8
16 A
9
20 A
A
30 A
B
32 A
C
64 A
D
Return to factory setting (16 A)
E
Testing mode
See position 2
F
Normal operation
Setting for normal charging operations
The following settings can be selected using the S3 rotary encoder on the right:
Position
Description
Explanation
0
Normal operation
Setting for normal and testing operations
1
0x01
When the S1 rotary encoder is set to position 3 (see above)
you can allocate the wallbox a different device ID using
the positions of the S3 encoder. Changing the device ID is
intended for future applications and currently does not
affect the operation of the wallbox. It is therefore recom-
mended not to make any changes and to generally leave
the S3 rotary encoder in the 0 position.
2
0x02
3
0x03
4
0x04
5
0x05
6
0x06
7
0x07
8
0x08
9
0x09
A
0x0A
B
0x0B
C
0x0C
D
0x0D
E
0x0E
F
0x0F
Taking the product out of and back into operation.
If required, you can take the wallbox out of operation. To take the wallbox out of operation, please pro-
ceed as follows:
1. Switch off the external RCCB (connection to the electricity grid is interrupted).
2. In addition, switch off the upstream MCB(s).
3. Always observe the five golden rules of electrical installation!
Now, no charging procedure can be carried out with the wallbox and it can be uninstalled if required.
To take the wallbox back into operation at a later time, please proceed as follows:
1. Switch on the upstream MCB(s).
2. In addition, switch on the external RCCB (connection to the electricity grid is established).
Summary of Contents for 3W72S2
Page 1: ...smart Wallbox Installation manual for specialist electrical contractors...
Page 4: ......
Page 35: ...smart Wallbox 31...