smart Wallbox
Preparations, installation and taking into operation
7
Identifying your model variant.
The smart Wallbox is available in a range of model variants that are mechanically and electrically tai-
lored to different usage patterns.
An additional product label with the specific smart product iden-
tification number for the wallbox is located on the underside of the
wallbox. For identification, the model code (A000 906 XX XX) as well
as the power supply ratings (voltage, frequency, current) indicated
below it are especially relevant.
When you open the housing cover for installation, you will find
behind it an additional product information label on the lower part
of the electronic components cover, which will also carry the ABL
model number.
Using the smart product identification number, please always en-
sure before installation that your wallbox model variant is the one
whose installation is described in this document.
The following wallbox model variant is the subject of this manual:
smart product
identification number
ABL
model number
Grid connection
Model Variant
A0009069106
3W72S2
see product
sticker
Fixed charging cable according to IEC 62196-
2 Type 1, ca. 7.4 m; charging output 7.2 kW
WARNING!
The information and technical specifications contained in this manual relate exclusive-
ly to the model variant mentioned in this manual and must not be transferred to other
wallbox models. These variants include specific instruction manuals where necessary.
Should your wallbox variant not be described in this manual, please contact your local
smart technical support service: Do not under any circumstances install the wallbox in
this case, as this could lead to damage to the wallbox, to injury and/or death.
General requirements of the installation site.
Your smart Wallbox is an electrical device and is therefore subject to particular requirements for indoor
and outdoor installation. In selecting the installation site, you must consider the following points:
> Consider all local regulations for electrical installations, fire protection and accident prevention.
> The wallbox must be installed where it is freely accessible to all authorized users.
> A parking spot must also be planned for in front of the wallbox so that the vehicle can at all times be
reached with the integrated or with an external charging cable.
3W22S200001
120 to
140 cm
> The recommended installation height is 120 to 140 cm from the floor to the
lower edge of the housing. This recommendation may be adjusted upwards
or downwards depending on local conditions. Sufficient air circulation must
be ensured at the installation site so that the wallbox is cooled during op-
eration: Always observe the allowed operating temperatures (see “Technical
specifications.” on page 23).
> The mounting area must have an even surface that provides sufficient sta-
bility for installing the wallbox.
> The required mounting area for the smart Wallbox is at least 512 x 429 mm
(H x W). All of the mounting plate of the wallbox must be in contact with the
mounting surface.
> To ensure the safe operation of the wallbox, minimum clearances of 50 cm
must be kept on all sides of the housing.
> In general, the wallbox is engineered for operation in high ambient tem-
peratures. However, it must be ensured that the maximum operating tem-
perature is not exceeded through external influences such as direct sunlight
or similar.
> The wallbox meets the requirements for outdoor installation. Outdoors, the
wallbox should only be installed in covered locations that provide sufficient protection from weath-
er-related pollution.
Requirements for the power supply.
The following standards must always be considered for the electrical installation of the smart Wallbox:
> All regulatory requirements for low voltage installations according to IEC 60364-1 and IEC 60364-5-
52 apply.
> Model variant A0009069106 is intended for the rated voltage indicated on the product sticker.
> The installation site must offer a sufficiently dimensioned power supply according to HD 60364-7-
722:2012 (see also “Guidelines & Norms.” on page 26): This power supply must be reserved exclu-
sively for the wallbox and must not be used to supply other electrical devices.
> If necessary, a separate power supply must be installed that is intended exclusively for connecting
the wallbox and complies with the general requirements for cabling and building infrastructure.
> Depending on the desired rated power, the installation of the wallbox may need to be registered with
and/or approved by the local electricity grid operator. Please consult the local regulations of your
electricity grid operator.
> Cable dimensions must be adjusted according to the desired rated power and other aspects (such
as cable length, material, cabling method etc.). The terminal blocks in the wallbox are designed for
cable dimensions of up to 16 mm
2
.
> The power supply cables may be installed above or below the wall surface: The mounting plate pro-
vides alternative cable inlets at the top and at the rear.