If – the vacuum pump starts and runs constantly, possibly with dropping pressure, when the slide
valve is opened, in connection with suction of work.
Check that all suction cups bear correctly on the work, i.e. that the particular suction cup is parallel with the
work, and that no parts of the suction cups protrude from the work (IMPORTANT !!!).
If – the vacuum pump starts and stops at very brief intervals.
Dismantle spiral hoses at couplings and close the slide valve if this has not been done already. If the
vacuum pump still starts and stops at very brief intervals, there may be a fault on the check valve.
If – the vacuum pump starts and runs, and stops at brief intervals, possibly with dropping pressure
on one or both pressure gauges, when the slide valve is opened, after correct suction of work.
Close slide valve. Disconnect one vacuum circuit at hose coupling, and then open the slide valve for vacuum
suction again. If the vacuum suction on the pressure gauge for disconnected circuit is now constantly 0.6,
there will be a fault on the hose set or at the suction cups in disconnected vacuum circuit. Test the same
procedure in case of fault on the other vacuum circuit system. You may listen for leaks.
Vacuum Guard
Bottom of
Smartlift
Vacuum pumps
Check Valves 2 circuits
Vacuum Guard light green when
pump is running (2 circuits system)
Vacuum Guard light red
when correct vacuum
suction reached
Filters
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
Vacuum filters
Summary of Contents for SL 380 MIDI
Page 16: ...US SL 380 MIDI 03 2016 16 LOAD DIAGRAM 2006 Copyright www smartlift dk...
Page 28: ...US SL 380 MIDI 03 2016 28 WIRING DIAGRAMS 2006 Copyright www smartlift dk...
Page 29: ...US SL 380 MIDI 03 2016 29 2006 Copyright www smartlift dk...
Page 30: ...US SL 380 MIDI 03 2016 30 2006 Copyright www smartlift dk...