If –no response when pushing control panel , individual functions
,
Has the safety switch been activated? If activated, try one of the possibilities above.
There may be a fault on actuators for movements, or when controlling these.
Actuators, and Control of these
For faults on movements of actuators, always first check visually and by review of the machine whether
anything visible is wrong, or “wrong” from an acoustic point of view, from one of the actuators. Lines may
be loose or torn, and bolts may be loose. Finally, the actual actuator telescopic arm may be bent. The
machine has totally five actuators. 1 for tilting of yoke, 2 for lifting of arm, 1 for telescoping of arm, and 1
for side change.
In particular lines at the bottom of these two lift actuators may, by carelessly wrong and unfortunate
operation of SL-380, have been damaged at connector or line.
Actuator for tilting
Actuators for lift
Emergency
Stop
Main switch to
be turned
clockwise to be
on
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
Line should be in holders