background image

US SL 380 MIDI 03-2016 

 

Drive 

 

 

47 

48 

Motor 0.95 hp /24 V 

47a 

On/OFF  Switch for Drive Motor 

47b 

Fuse 80 Amperes Motor 

48 

Regulating Lever 

49 

Curtis Motor Control 

50 

Safety Clamp 

51 

Safety Switch 

52 

Forward and Back Switch 

53 

Protective Cap for forward and back switch   

 

Transport/Handling 

 

Smart Lift is for indoor use.  

 

Prior to transport, switch off all electronics on main switch (pos. 38). 

 

Smart Lift to be fastened securely in truck/trailer for transport and protected against rain and 

snow. 

 

Lifting by crane or similar: Always lift Smart Lift in lift eye intended for this purpose (pos. 41). 

 

NEVER lift under Smart LIFT by forks (truck and similar) 

 

For transport on the transport frame, Smart Lift must always be fastened in the lock fitting (pos. 

42). 

 

Do not expose to rain and snow 

 

Putting into Operation 

 

Prior to putting into operation, insert vacuum hoses, and charge battery fully. 

 

If the yoke has been dismantled, be aware that the washer is placed between the castle nut and 

the yoke.  

 

 

Storage 

 

Always switch off your Smart Lift on the main switch (pos. 38), before storage. 

 

Smart Lift should be kept in a dry place. 

Moisture may affect the machine functionality.

 

 

Batteries should always be fully charged. 

Summary of Contents for SL 380 MIDI

Page 1: ...I 03 2016 1 User Manual Model type SL 380 MIDI 0 95 hp N A Christensensvej 39 DK 7900 Nyk bing Mors Tlf 45 97 72 29 11 Fax 45 97 72 39 11 E mail smart smartlift dk www smartlift dk 2006 Copyright www...

Page 2: ...w General Description 8 Operation for Vacuum function 10 Control for arm and yoke 10 Important Operation vacuum electric functions 11 Electric Functions 11 Charger Battery Case 12 View of Vacuum syste...

Page 3: ...guarded This is why safety rules have been prepared by way of warnings in this instruction Read these safety rules on the following pages before putting your Smart LIFT into operation and imagine how...

Page 4: ...reached by upper and lower limbs DS EN ISO 13849 1 Safety of machinery Safety related parts of control systems Part 1 General principles for design DS EN 13155 A2 Cranes Safety Non fixed load lifting...

Page 5: ...p MRX 80 P M10 25 6 21 Actuator Tilting function LA 36 1 22 Actuator Side Change 1 23 Actuator Telescopic Arm 1 24 Actuator Lift Arm LA 36 2 Power Supply 25 Battery 62 AK Battery Case 2 26 Charger CTE...

Page 6: ...now Lifting by crane or similar Always lift Smart Lift in lift eye intended for this purpose pos 41 NEVER lift under Smart LIFT by forks truck and similar For transport on the transport frame Smart Li...

Page 7: ...oose objects on the machine since this would entail breakdown and danger risks WARNING Vacuum Working at the machine will entail danger if the various safety devices pressure gauge pos 6 and acoustic...

Page 8: ...work is strictly prohibited PROHIBITED May NOT be used for person lifting Overview General Description pages 8 9 11 14 Telescopic Arm 21 Actuator tilting function 2 Suction Cups diam 11 8 in Vacuum Ch...

Page 9: ...activation and deactivation of vacuum suction 2 circuit system 32 Control Panel in holder 5 Slide Valve w lock Vacuum 2006 Copyright www smartlift dk 2006 Copyright www smartlift dk 31 Overload safety...

Page 10: ...h the functioning of the machine Smart LIFT is operated manually This machine generally has four functions which may be operated individually UP DOWN function This function will make the arm move eith...

Page 11: ...ctivating the safety switch will stop the car and the car will move forward Important Operation vacuum electric function 51 Safety function f back machine moving forward automatically 32 Control Panel...

Page 12: ...a maximum charge time of 18 hours Connection to the mains or reduction of the output voltage to 12V resp 24V due to a DC load will trigger a new charge cycle Also please refer to the attached user gu...

Page 13: ...acuum Load Diagram 2006 Copyright www smartlift dk 17 Line filter f vacuum suction 1 Vacuum pump 2006 Copyright www smartlift dk For max stability at transport of sucked work the suction cups are to b...

Page 14: ...f the battery case Must be switched off after use 2006 Copyright www smartlift dk 2006 Copyright www smartlift dk 34 Controller lifting arm 39 Fuse 30 Ampere 36 Controller side shift 35 Controller tel...

Page 15: ...80 MIDI 03 2016 15 Control Panel for arm and yoke pos 32 Lift Arm Down Tilt back Telescopic arm out Side shift left Lift arm up Tilt forward Telescopic Arm in Side shift right 2006 Copyright www smart...

Page 16: ...US SL 380 MIDI 03 2016 16 LOAD DIAGRAM 2006 Copyright www smartlift dk...

Page 17: ...icator Has the emergency stop button switched the machine off placed on grey control box Has the safety switch been switched off on account of overloading placed under pressure switches Is the hose se...

Page 18: ...stantly appr 0 55 or less and the pump is running In that case there would be a fault on the vacuum pump or a leak on the hose connection between check valve and vacuum pump If the pressure gauge indi...

Page 19: ...rvals possibly with dropping pressure on one or both pressure gauges when the slide valve is opened after correct suction of work Close slide valve Disconnect one vacuum circuit at hose coupling and t...

Page 20: ...cator Is 30 ampere fuse in control box OK Has the safety switch been activated If activated try to deactivate by pulling in the telescopic arm or act as follows The safety switch has correctly switche...

Page 21: ...ew from one of the actuators Lines may be loose or torn and bolts may be loose Finally the actual actuator telescopic arm may be bent The machine has totally five actuators 1 for tilting of yoke 2 for...

Page 22: ...ctuator for side change 80 A Fuse f drive motor If the lift actuators or one of these stop due to unbalanced load one of the safety switches under the actuators will have switched off the power supply...

Page 23: ...r all actuators Faults on movement of actuators can be diagnosed by measuring systematically as described in the following two pages Controller for tilting actuator Controller for telecoping actuator...

Page 24: ...the remote control Voltage between clamp 1 and 9 and 1 and 10 must be approx 24 Volt Possible faults on pulses from lifting actuator can be checked by activating the control panel in steps At the same...

Page 25: ...ween Clamps 1 and 6 as between 1 and 7 Fault on remote control when moving single actuators Voltage must be 24 Volt between clamps 1 and 9 as between 1 and 10 Activate the control panel for movement o...

Page 26: ...the screen at the front of the machine OK Check regulating lever and cables for visible faults and damage There may be no faults on lever or control unit Control light on switch may show error code a...

Page 27: ...mplete manual refer to https www victronenergy com upload documents Datasheet Blue Power Battery Charger IP65 90 135VAC EN pdf LED indication Description Yellow LED on battery being charged Yellow LED...

Page 28: ...US SL 380 MIDI 03 2016 28 WIRING DIAGRAMS 2006 Copyright www smartlift dk...

Page 29: ...US SL 380 MIDI 03 2016 29 2006 Copyright www smartlift dk...

Page 30: ...US SL 380 MIDI 03 2016 30 2006 Copyright www smartlift dk...

Reviews: