US SL 380 MIDI 03-2016
26
3. Stop-Down at Drive Section
If - no response at activation on regulating lever
(no click sound)
Check whether the main switch is on – to be turned clockwise to switch on. Has the red On/Off switch on
the regulating lever been put into On position (green lamp on)? Have batteries been charged (check
indicator)?
Is the 80-ampere fuse beside the motor control under the screen at the front of the machine OK?
Check regulating lever and cables for visible faults and damage. There may be no faults on lever or control
unit.
Control light on switch may show error code at various flash signals (contact Smartlift).
Fuse 80 A for drive
© 2006 Copyright. www.smartlift.dk
© 2006 Copyright. www.smartlift.dk
Regulation lever
forward/back
High/low speed
Safety button for back
function. The machine
drives forward when
activated
If the yoke has been dismantled, be aware
that the washer is placed between the
castle nut and the yoke.
Tighten by hand
ON/OFF-switch
Summary of Contents for SL 380 MIDI
Page 16: ...US SL 380 MIDI 03 2016 16 LOAD DIAGRAM 2006 Copyright www smartlift dk...
Page 28: ...US SL 380 MIDI 03 2016 28 WIRING DIAGRAMS 2006 Copyright www smartlift dk...
Page 29: ...US SL 380 MIDI 03 2016 29 2006 Copyright www smartlift dk...
Page 30: ...US SL 380 MIDI 03 2016 30 2006 Copyright www smartlift dk...