Fault on lift actuator
Here, too, all lines should be undamaged, and placed correctly at lead-ins etc.
To check this actuator, remove the protective screen. In case of lacking or wrong function, check for any
murmuring/noise and loose lines.
Actuator for telescoping of arm
Actuator for side shift
Motor control for drive motor with fuse for
same. Nothing to do with actuator for side
change.
80 A Fuse f/drive motor
If the lift actuators, or one of these, stop due to “unbalanced” load, one of
the safety switches under the actuators will have switched off the power
supply. The following may be done to re-establish normal function:
Pushing the operation panel button repeatedly to function ”down” will run
lift actuators to bottom position, and both actuators should run
synchronously again.