4.4 Reference Input Selection (IN0, IN1, IN2, XA/XB)
The active clock input is selected using the IN_SEL1,0 pins or by register control. The register bit IN_SEL_REGCTRL determines input
selection as pin or register selectable. If the selected input does not have a clock, all output clocks will be shut off.
Table 4.1. Manual Input Selection Using IN_SEL[1:0] Pins
IN_SEL[1:0]
Selected Input
0
0
IN0
0
1
IN1
1
0
IN2
1
1
XA/XB
Table 4.2. Input Control Registers
Register Name
Hex Address [Bit Field]
Function
Si5341
Si5340
XAXB_FREQ_OFFSET
0202[7:0]–0205[7:0]
Adjusts for crystal load capacitance mismatch causing oscillation
frequency errors up to ±1000 ppm. This word is in 2s complement
format.
The XAXB_FREQ_OFFSET word is added to the M divider nu-
merator.
XAXB_EXTCLK_EN
090E[0]
Selects between the XTAL or external reference clock on the
XA/XB pins. Default is 0, XTAL. Set to 1 to use an external refer-
ence oscillator
IN_SEL_REGCTRL
0021[0]
Determines pin or register clock input selection.
IN_SEL
0021[2:1]
Selects the input when in register input selection mode.
IN_EN
0949[3:0]
Allows enabling/disabling IN0, IN1, IN2 and FB_IN when not in
use.
Table 4.3. XAXB Pre-Scale Divide Ratio Register
Setting Name
Hex Address [Bit Field]
Function
PXAXB
0x0206[1:0]
Sets the XAXB input divider value according to the table be-
low.
The following table lists the values, along with the corresponding divider ratio.
Table 4.4. XAXB Pre-Scale Divide Values
Value (Decimal)
PXAXB Divider Value
0
1
1
2
2
4
3
8
Si5341, Si5340 Rev D Family Reference Manual • Clock Inputs