4.5.1 Status Indicators
The state of the status monitors are accessible by reading registers through the serial interface or with dedicated pin (LOLb). Each of
the status indicator register bits has a corresponding sticky bit (_FLG) in a separate register location. Once a status bit is asserted its
corresponding _FLG bit will remain asserted until cleared. Writing a logic zero to a _FLG register bit clears its state.
Table 4.5. Status Monitor Bits (Si5341 and Si5340)
Setting Name
Hex Address [Bit Field]
Function
Status Register Bits
SYSINCAL
0x000C[0]
Asserted when in calibration.
LOSXAXB
0x000C[1]
Loss of Signal at the XA input.
The XB input does not have an LOS detector.
LOSREF
0x000C[2]
Loss of Signal for the input that has been selected.
LOL
0x000C[3]
Loss of Lock for the PLL.
SMBUS_TIMEOUT
0x000C[5]
The SMB bus has a timeout.
LOSIN[3:0]
0x000D[3:0]
Loss of Signal for the FB_IN, IN2, IN1, IN0 inputs.
Sticky Status Register Bits
SYSINCAL_FLG
0x0011[0]
Sticky bit for SYSINCAL
LOSXAXB_FLG
0x0011[1]
Sticky bit for LOSXAXB
LOSREF_FLG
0x0011[2]
Sticky bit for LOSREF
LOL_FLG
0x0011[3]
Sticky bit for LOL
SMBUS_TIMEOUT_FLG
0x0011[5]
Sticky bit for SMBUS_TIMEOUT
LOSIN_FLG
0x0012[3:0]
Sticky bit for FB_IN, IN2, IN1, IN0