1 – Read
0 – Write
A – Acknowledge (SDA LOW)
N – Not Acknowledge (SDA HIGH)
S – START condition
P – STOP condition
Write Operation – Single Byte
S
0 A Reg Addr [7:0]
Slv Addr [6:0]
A
Data [7:0]
P
A
Write Operation - Burst (Auto Address Increment)
Reg Addr +1
S
0 A Reg Addr [7:0]
Slv Addr [6:0]
A
Data [7:0]
A
Data [7:0]
P
A
Host
Si5341/40
Host
Si5341/40
Figure 8.4. I
2
C Write Operation
A read operation is performed in two stages. A data write is used to set the register address, then a data read is performed to retrieve
the data from the set address. A read burst operation is also supported as shown in the following figure.
1 – Read
0 – Write
A – Acknowledge (SDA LOW)
N – Not Acknowledge (SDA HIGH)
S – START condition
P – STOP condition
Read Operation – Single Byte
S
0 A Reg Addr [7:0]
Slv Addr [6:0]
A P
Read Operation - Burst (Auto Address Increment)
Reg Addr +1
S
1 A
Slv Addr [6:0]
Data [7:0]
P
N
S
0 A Reg Addr [7:0]
Slv Addr [6:0]
A P
S
1 A
Slv Addr [6:0]
Data [7:0]
A
P
N
Data [7:0]
Host
Si5341/40
Host
Si5341/40
Figure 8.5. I
2
C Read Operation
Si5341, Si5340 Rev D Family Reference Manual • Serial Interface