14.2.7 Page B Registers Si5341
Table 14.90. 0x0B2E Synchronous Output Disable Timeout Value
Reg Address
Bit Field
Type
Setting Name
Description
0x0B2E
6:0
R/W
MS_OD_G_TIME-
OUT
Controls the synchronous output disable timeout value
during a hard reset.
0x0B2E
7
R/W
MS_OD_G_TIME-
OUT_EN
Table 14.91. 0x0B4A Divider Clock Disables
Reg Address
Bit Field
Type
Setting Name
Description
0x0B4A
4:0
R/W
N_CLK_DIS
Controls the clock to the N divider. If an N divider is
used the corresponding bit must be 0. [N3 N2 N1 N0].
See also registers 0x0A03 and 0x0A05.
Table 14.92. 0x0B57
Reg Address
Bit Field
Type
Name
Description
0x0B57
7:0
R/W
VCO_RESET_CAL-
CODE
12-bit value
0x0B58
11:8
R/W
VCO_RESET_CAL-
CODE
14.3 Si5340 Registers
Because preprogrammed devices are inherently quite different from one another, the default power up values of the registers can be
determined using the
. Some registers that are listed in the Data Sheet Addendum are not documented in the
Register Map below because they are set and maintained by Clock Builder Pro. In almost all circumstances, these registers should not
be modified by the user. For more details, contact
Silicon Labs technical support
.