14.2.5 Page 9 Registers Si5341
Table 14.81. 0x090E XAXB Configuration
Reg Address
Bit Field
Type
Setting Name
Description
0x090E
0
R/W
XAXB_EXTCLK_EN 0 to use a crystal at the XAXB pins
1 to use an external clock source at the XAXB pins. A
singled ended clock must be applied at the XA input.
0x090E
1
R/W
XAXB_PDNB
0-Power down the oscillator and buffer circuitry at the
XA/XB pins
1- No power down
Table 14.82. 0x091C Enable Zero Delay Mode
Reg Address
Bit Field
Type
Setting Name
Description
0x091C
2:0
R/W
ZDM_EN
3 = Zero delay mode.
4 = Normal mode.
All other values must not be written.
Table 14.83. 0x0943 Status and Control I/O Voltage Select
Reg Address
Bit Field
Type
Setting Name
Description
0x0943
0
R/W
IO_VDD_SEL
0 for 1.8 V external connections
1 for 3.3 V external connections
The IO_VDD_SEL configuration bit selects the option of operating the serial interface voltage thresholds from the VDD or the VDDA
pin. By default the IO_VDD_SEL bit is set to the VDD option. The serial interface pins are always 3.3 V tolerant even when the device's
VDD pin is supplied from a 1.8 V source. When the I
2
C or SPI host is operating at 3.3 V and the Si5341/40 IO_VDD_SEL = 1.8 V,
the host should write the IO_VDD_SEL configuration bit to the VDDA option. This will ensure that both the host and the serial interface
are operating at the optimum voltage thresholds. The IO_VDD_SEL bit also affects the status pin levels and control pin thresholds.
When IO_VDD_SEL = 0, the status outputs will have a VOH of ~1.8 V. When IO_VDD_SEL = 1 the status outputs will have a VOH of
~3.3 V. When IO_VDD_SEL=0, the control input pins will have an input threshold based upon the VDD supply voltage of 1.8 V. When
IO_VDD_SEL=1, the control input pins will have an input threshold based upon the VDDA supply voltage of 3.3 V. See Table 4 and
Table 6 of the Si5341/40 data sheet for details.
Table 14.84. 0x0949 Clock Input Control
Reg Address
Bit Field
Type
Setting Name
Description
0x0949
3:0
R/W
IN_EN
Enables for the four inputs clocks, IN0 through FB_IN.
1 to enable, 0 to disable
• Input 0 corresponds to IN_EN 0x0949 [0].
• Input 1 corresponds to IN_EN 0x0949 [1].
• Input 2 corresponds to IN_EN 0x0949 [2].
• FB_IN corresponds to IN_EN 0x0949 [3].
Si5341, Si5340 Rev D Family Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
82
Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021
82