IDP 700 Terminal Series - Hardware Guide
T206, Version 01 52 © SkyWave Proprietary
Figure 54 Insert Inner Conductor
4.
Insert the main body into the braid and dielectric until it pushes against the insulator
(Figure 55).
Figure 55 Insert Main Body
5.
Slide the ferrule over the braid and crimp or solder (Figure 56).
Figure 56 Slide Ferrule
6.
Insert the main body into the plastic housing and press the locking clip into it
(Figure 57).You should hear a snap.
Figure 57 Main Body and Plastic Housing
7.
Verify the pin height from the end of SMB metal body to the top of the contact
(1.18-1.81 mm).
Cable
Group
Stripping Length (mm)
Center
Contact
Crimp Tool
Ferrule
Crimp
Size
A
B
C
1
3 mm
2.8 mm
5.2 mm
AFM8
Hex 3.25 mm
4
3 mm
1.7 mm
8.3 mm
AFM8
Hex 5.41 mm
9
2.4 mm
5.8 mm
5.7 mm
AFM8
Hex 3.25 mm
10
3 mm
2.6 mm
5.2 mm
AFM8
Hex 3.25 mm
Please refer to FAKRA catalog for recommended tools.