IDP 700 Terminal Series - Hardware Guide
© SkyWave Proprietary 35 T206, Version 01
Figure 36 Air Vent Feature
5.
Secure the antenna in place with self-tapping screws or machine screws and nuts
depending on access to the mounting surface. The remote antenna may also be
mounted using adhesive or a high strength outdoor grade silicone when mounting
holes are not an option in the mounting surface.
6.
Connect the SMA connector on the remote antenna cable to the SMA connector on
the mobile device and torque to 1.7 N-m.
Note:
The recommended torque specification is approximately finger tight plus a
45 degree rotation using an 8 mm wrench.
CAUTION
Cable management and connector strain relief must be
incorporated in the installation. Secure the cable no more
than 15 cm from the enclosure and at regular intervals along
its length as part of the installation to prevent cable wear and
eliminate strain on the mobile device connector. Damage to
the connector interface or cable may otherwise result leading
to hardware failure.