IDP 700 Terminal Series - Hardware Guide
© SkyWave Proprietary 15 T206, Version 01
3.8.1
CAN
The driver provides CAN Bus link layer interfaces for sending and receiving frames.
Open/Close CAN device.
Configure/change CAN frame format, baud rate, acceptance filters.
Interrupting service for receive, transmit.
Receive and transmit message queue management.
CANbus
Parameter
Value
Operating Mode
Half-duplex
Version
2.0 A, B
Supported Data Rate
Up to 1 Mbps
Filter Banks
14
3.8.2
RS-485
The electrical characteristics of the interface are:
Parameter
Minimum
Typical
Maximum
Units
Input Common Mode Voltage
-7.0
-
+12
V
Differential Input Threshold
-200
-125
-50
mV
Output Common Mode Voltage
-
1.5
3.0
V
Differential Drive Output, 54 Ω load
1.5
-
-
V
3.8.3
RS-232
The RS-232 interface defaults to the following settings: 9600 bit/s, 1 start, 8 data, 1 stop
bit, no parity. The baud rate is configurable up to 230,400 bit/s.
The electrical characteristics of the interface are:
Parameter
Minimum
Typical
Maximum
Units
Serial Rx Input Low Threshold
-2.7
-
-
V
Serial Rx Input High Threshold
-
-
2.7
V
Serial Tx Low Output
(3 K load)
-
-
-3.7
V
Serial Tx High Output
(3 K load)
3.7
-
-
V