Page 33
INE S.p.A.
Via Facca, 10 - 35013 Cittadella - PADOVA - ITALIA Tel. 049/9481111 - Fax 049/9400249 - [email protected] - www.ine.it
In case of TIG welding:
•
Connect the gas hose between the gas cylinder
(equipped with flow meter and pressure reducer)
and the socket ‘G1’ on the power source rear panel;
connect the TIG torch to the socket ‘A3’ on the front
panel. Connect the torch gas hose and the torch
trigger wire to the corresponding ’G2’ and ‘C3’
connectors on the front panel.
•
Connect the work return lead to the socket ‘A2’ on
the power source and clamp it to a clean area of the
workpiece.
In the case of MMA welding:
•
Connect the electrode holder to its socket (positive
‘A2’ or negative ‘A3’), as requested by the type of
electrode.
•
Connect the work return lead to the free socket on
the power source and clamp it to a clean area of the
workpiece.
13 Lifting: indications and precautions
To lift the machine use
only the 4 holes
on
the base of the generator trolley PR8: take
care to ensure that the lifting cables form a
small angle with respect to the vertical. All
the movable parts on the machine –
e.g. gas
cylinder, generator-wire feeder extension, wire
feeder, torches, earth cables, etc.
– must be removed
to avoid uncontrollable falls of all or part of the lifted
load.
The machine is to be positioned on a solid
and stable surface or floor which is adequate
to the machine’s weight. The maximum
inclination allowed is of 10°.
H
SI
L
G
N
E
MAX
15°
A3
G2
C3
A2
G1
A1
C2
C1
optional
Summary of Contents for KMP3200