208932AEA
SJ85AJ
46
Section 4 – Pre-operation
Function Tests
4.3-4 Test Start/Function Enable/
Emergency Power Switch and All
Boom and Platform Functions
WARNING
Ensure that there are no personnel or obstructions
in test area and there is sufficient room for boom
to swing.
1.
Ensure
emergency stop button is pulled
out.
2.
Start engine.
3.
Do not hold
start/function enable/
emergency power switch in function enable
position. Attempt to activate each boom and
platform switch.
▪
Result:
All boom and platform functions
should not operate.
4.
Hold
start/function enable/emergency
power switch in function enable position and
activate each boom and platform function.
▪
Result:
Engine speed increases from idle to
intermediate. All boom and platform functions
should operate as selected.
4.3-5 Test Platform Self-leveling
1.
Lower boom to stowed position.
2.
Adjust platform to a level position using platform
leveling switch, which controls
tilting up or
tilting down of platform.
3.
Fully raise
main boom.
▪
Result:
Platform should remain level at all
times and lifting speed should slow down
before boom reaches full height.
4.
Fully lower
main boom.
▪
Result:
Platform should remain level at all
times.
TM
!
HOUR METER
QUARTZ
Base Control Console
Start/Function Enable/
Emergency Power Switch
Off/Base/Platform Key
Switch
Emergency Stop
Summary of Contents for SJ85AJ
Page 1: ...OPERATING MANUAL SJ85AJ ARTICULATING BOOMS 208932AEA November 2018 AS...
Page 4: ...208932AEA SJ85AJ 4 Notes...
Page 18: ...208932AEA SJ85AJ 18 Notes...
Page 62: ...208932AEA SJ85AJ 62 Notes...
Page 68: ...208932AEA SJ85AJ 68 Notes...
Page 69: ...SJ85AJ 208932AEA 69 Section 7 Technical Diagrams Specifications...
Page 78: ...208932AEA SJ85AJ 78 Notes...
Page 102: ...208932AEA SJ85AJ 102 Notes...
Page 104: ...208932AEA SJ85AJ 104 Notes...
Page 105: ......
Page 106: ...www skyjack com...