208932AEA
SJ85AJ
48
Section 4 – Pre-operation
Function Tests
4.3-8 Test Off/Base/Platform Switch
1.
Ensure both
emergency stop buttons at
base and platform are pulled out.
2.
Start engine.
3.
On base control console, turn off/base/platform
key switch to
off position.
▪
Result:
Engine should shut down and MEWP
functions should not operate.
4.
On base control console, turn off/base/platform
key switch to
platform position.
WARNING
Ensure that you maintain three points of contact to
mount/dismount platform.
5.
Enter platform and close gate/drop bar.
6.
Select
start position from engine start/on/off
switch until engine starts.
7.
Dismount from platform.
8.
On base control console, attempt to activate
each boom and platform switch while holding
start/function enable/emergency power switch in
function enable position.
▪
Result:
All boom and platform functions
should not operate while holding start/function
enable/emergency power switch in function
enable position.
9.
Push in
emergency stop button to turn
engine off.
10.
Pull out
emergency stop button.
TM
!
HOUR METER
QUARTZ
Base Control Console
Start/Function Enable/
Emergency Power Switch
Off/Base/Platform Key
Switch
Emergency Stop
Summary of Contents for SJ85AJ
Page 1: ...OPERATING MANUAL SJ85AJ ARTICULATING BOOMS 208932AEA November 2018 AS...
Page 4: ...208932AEA SJ85AJ 4 Notes...
Page 18: ...208932AEA SJ85AJ 18 Notes...
Page 62: ...208932AEA SJ85AJ 62 Notes...
Page 68: ...208932AEA SJ85AJ 68 Notes...
Page 69: ...SJ85AJ 208932AEA 69 Section 7 Technical Diagrams Specifications...
Page 78: ...208932AEA SJ85AJ 78 Notes...
Page 102: ...208932AEA SJ85AJ 102 Notes...
Page 104: ...208932AEA SJ85AJ 104 Notes...
Page 105: ......
Page 106: ...www skyjack com...