71
SKOPE VF Series
Replacement Procedures
Service Manual
Compressor
Electrics
The compressor electrics are located around the compressor and differ
between refrigeration units.
Compressor
The compressor type varies between refrigeration units. Refer to “Unit
specifications” on page 61 for compressor specifications.
Before replacing the compressor, ensure the compressor electrics are
operating correctly and that the compressor is being supplied with
consistent voltage over 220 volts. Ensure the voltage does not drop at
startup. If the voltage does drop, ensure the unit has a direct power supply
(not from a multi-box or extension cord).
If the compressor is causing excessive noise check the mountings to ensure
there is no damage to the rubber or the washers, nuts and screws.
Figure 12: UF30AAD
compressor electrics
Figure 13: UF40AAD
compressor electrics
Figure 14: UF50AAD
compressor electrics
Start relay
(behind cover)
Start capacitor
Start relay
Start capacitor
Run capacitor
Start relay
Start capacitor
Run capacitor