![Skope VF1000-ICE Service Manual Download Page 56](http://html1.mh-extra.com/html/skope/vf1000-ice/vf1000-ice_service-manual_1289218056.webp)
56
Replacement Procedures
Service Manual
SKOPE VF Series
Doors
Depending on the model, the cabinet is fitted with one, two or three glass
paned or solid foam filled doors. Door hinging can be reversed if desired
(see “To reverse the door hinging” on page 59).
Alignment
If a door is out of alignment, follow the steps below to realign the door.
To realign the door
Gasket
Replacement
The door gasket clips into the door gasket retainer extrusion on the inside of
the door and may be removed for repair or replacement by peeling from the
frame, starting at a corner.
New gaskets, when fitted, can be lightly lubricated with a clear silicone
grease or similar compound to lessen the possibility of the gasket rolling.
Should the gasket be out of shape when in place, use hot air (i.e. from hair
drier) to realign.
1. Loosen the two bottom
hinge fixing screws.
2. Move the bottom hinge left
or right along the screw hole
slots to align the door.
3. Tighten the two bottom
hinge fixing screws.
Bottom hinge
fixing screws
Bottom hinge
fixing screws
Bottom hinge
Door Gasket
Gasket Retainer
Door Frame
Figure 5: Door Gasket