70
Replacement Procedures
Service Manual
SKOPE VF Series
4. Undo the fan motor
perimeter screws to
detatch the fan motor from
the fan motor mount, and
unplug the fan motor to
detatch from the unit.
When refitting or replacing
the fan, ensure the fan
motor is fitted in the
correct orientation with the
electrical flex outlet at the
bottom.
5. Connect the new fan motor wiring. The wiring diagrams below show EBM fan
motor wiring and UNADA fan motor wiring.
6. Reassemble the unit and perform electrical safety test
7. Test run the unit to confirm correct operation.The fan motors should run at
high speed (2200rpm) when the compressor is on, and low speed (1000rpm)
when the compressor is off.
EBM fan motor wiring (EBM
W1G200) (SKOPE part number
ELM9974)
UNADA fan motor wiring (UNADA-
UC FM103709R) (SKOPE part
number ELM11036)