SKOPE VF Series
SKOPE CAREL ir33 Controller
Service Manual
Default Program Configuration
Factory Default Configuration of the controller is set by SKOPE to a specific
SKOPE Product. The factory default cannot be altered in the field. A label on
the controller box indicates the default program configuration number (e.g.
VF Series integral ‘Program 485’).
BN Parameter
Sets
Program 485 includes 3 parameter sets (BN1, BN2 and BN3) for use with
VF Series cabinet variations. The BN set can be changed by performing a
controller reset (see “Controller Reset” on page 16) and selecting the
appropiate BN set. Refer to the table below for BN set operational mode
variations.
BN set variations
Field
Adjustable
Programming
Within each program set are field adjustable (Type C) parameters. To assist
with locating, the parameters can be displayed in groups detailed in the table
below. Non-useful parameters are hidden.
Parameter groups
Changes to SKOPE factory default programs are not recommended.
To access Type C parameters
Parameter set
Operational mode
485 BN1
Glass door lit
integral freezer &
solid door unlit
integral freezer
485 BN2
Solid door lit
integral freezer
485 BN3
Glass door ice
storage cabinet
Display Icon
Group
Display Icon
Group
Pro
Probe
Fan
Fan
Ctl
Temperature
CnF
General
CMP
Compressor
HcP
HACCP
dEF
Defrost
rtc
Real time clock
ALM
Alarm
1. Press the
key and
keys
together for more than 5 seconds.
The display will show either ‘
00
’ or ‘
-
1
’, representing the password
prompt.
2. Press the
or
keys until
displaying the password number ‘
66
’
Continued over page