61
SKOPE VF Series
Replacement Procedures
Service Manual
Refrigeration Unit
Introduction
SKOPE VF Series refrigeration units are top mounted, electronically
controlled removable cassettes.
For major servicing or transportation, the refrigeration unit unplugs and lifts
off the cabinet. Some servicing can be performed without removing the
refrigeration unit.
The model and serial number are both printed on the unit rating/serial
number label attached to the evaporator box below the unit junction box.
Before ordering spare parts take note of these numbers.
Specifications for the model are in the following table. Verify model and basic
requirements before servicing.
Unit specifications
Unit
UF30AAD
UF40AAD
UF50AAD
Used in
VF1300
VF650/VF1500
VF1000/VF1300
Compressor
Danfoss
SC18CLX.2
Danfoss GS26CLX Danfoss GS34CLX
Nominal capacity 1036 watts @ -30°C
evaporator & 50°C
condenser (freezer)
1776 watts @ -20°C
evaporator & 50°C
condenser (ice
storage cabinet)
752 watts @ -30°C
evaporator & 50°C
condenser (freezer)
1776 watts @ -20°C
evaporator & 50°C
condenser (ice
storage cabinet)
1097 watts @ -30°C
evaporator & 50°C
condenser (freezer)
1846watts @ -20°C
evaporator & 50°C
condenser (ice
storage cabinet)
Refrigerant
R404A
R404A
R404A
Charge
650g
700g