Skope OD1100N Service Manual Download Page 33

33

SKOPE OD1100N

Replacement Procedures

Service Manual

The fan motors and fan blades are fixed to the evaporator shroud with brackets. The shroud 

(complete with fan motors and fan blades) can be lifted off the evaporator tub. 

It is important that fan blades and fan motors are replaced with the same part to ensure safety, 

correct alignment and refrigeration performance, and compliance. When refitting or replacing 

fan motors, ensure that the blade screw is tightened to 1.5 Nm.

Fan motor

Evaporator shroud

Evaporator tub

Mounting 

bracket

IMPORTANT

Replace the motor with the same SKOPE OEM part.

DO NOT

 use alternative parts.

Procedure 22: To access the evaporator fan assembly

1. Disconnect the cabinet from the power supply (see page 18).

2. Remove the refrigeration cartridge (see page 28). The evaporator fan assembly can now be 

accessed.

Procedure 23: To replace the evaporator fan blade

1. Disconnect the cabinet from the power supply (see page 18).

2. Remove the refrigeration cartridge (see page 28).

3. Remove the screw and washer from the centre of the fan blade, and lift the blade from the motor.

4. Ensure the new blade is centred within the evaporator shroud, and reattach with a 12 mm flat 

washer and serrated head screw. Tighten the screw to 1.5 Nm.

5. Reassemble the cartridge and test for correct operation:

“To diagnose lack of gas” on page 27.

Test and tag.

Procedure 24: To replace the evaporator fan motor

1. Follow Procedures 22 and 23 to access the evaporator fan assembly and remove the fan blade.

2. Unscrew and remove the cartridge’s right hand side panel to access the fan motor cable 

connectors.

3. Lift the evaporator shroud (complete with fan motor) from the evaporator tub.

Note

: The evaporator and control probe flexible cords may restrict movement when lifting the 

shroud from the evaporator tub.

4. Free the fan flexible cord by cutting the cable ties and removing it from the evaporator tub edge 

putty.

5. Remove the four nuts and spring washers from the fan mounting brackets and lift the fan motor 

from the bracket.

Summary of Contents for OD1100N

Page 1: ...OD1100N Service Manual MAN80336 Rev 1 1 Sep 2022 SKOPE Open Deck Fridge Hydrocarbon...

Page 2: ...pe com Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following Applies the trade mark to the product after its state condition...

Page 3: ...lating Electrics 18 Security Grille optional 18 Kick Panel 19 Sign 19 Fitting and Removing the Sign 20 Cladding 21 Removing and Refitting the Cladding 21 Lighting 22 Shelf Lights 22 Cabinet Electrics...

Page 4: ...ng 40 Cabinet 40 Refrigeration Cartridge 42 Cartridge Electrics Box 44 Sign 45 High Sign 45 Low Sign 46 7 Maintenance Cleaning 47 Cabinet 47 Condenser Filter and Coil 47 8 Troubleshooting Electronic C...

Page 5: ...r Capacity L 1071 Shelves 4 adjustable angle 8 or flat adjustable height shelves 1 adjustable angle 8 or flat bottom shelf Optional gravity feed system available Top two shelves 1170W 360D middle two...

Page 6: ...cked into place This will provide the necessary air gap at the rear of the cabinet for correct operation Power Cord The fridge has a flexible power cord fitted with a 3 pin plug at the rear of the cab...

Page 7: ...ack of the shelf bracket 7 Select the new position and move the shelf brackets The shelves can be repositioned as far as the shelf light cable reasonably allows 8 Place the shelf and if present the gr...

Page 8: ...tting and shelf dividers 1 Match up the shelf dividers with the corresponding matting 2 Work across the matting and fit the centre dividers at required intervals 3 Place the mat and dividers onto the...

Page 9: ...mpressor S2 2 P2 2 BK BN S2 1 P2 1 BU BU BU LED Power Supply N L P9 1 S9 1 BU S9 1 P9 1 BN BN BU RD P12 S12 WH BK P11 S11 WH BK P14 S14 BK Control Sensor Evaporator Sensor Cabinet Lighting WH BK P13 S...

Page 10: ...vice agent Table 1 Controller Faceplate No Description Use 1 Night Mode Indicator On during night mode 2 Display Indicator Digital display of the cabinet s air not product temperature alarm messages 3...

Page 11: ...ngton Drive Technologies documentation for further information SCS Connect Field App Connecting The SCS Connect Field app gives authorised service technicians wireless access to the controller from mo...

Page 12: ...ooth logo indicates that the controller is currently connected to a device 2 Open the SCS Connect Field app 3 Select the controller from the list of visible controllers Note This list is filtered by y...

Page 13: ...activity including temperatures and alarms SCS info Displays information about the cabinet and the controller version SCS setup Allows you to add or change SCS info see above Disconnect Allows you to...

Page 14: ...nser is free of debris If the coil is dirty clean it with a vacuum cleaner or soft brush Poor installation or ventilation Check the installation guidelines If fitted check the rear stand offs are exte...

Page 15: ...le Check if the return air grille is covered by product If so move the product from the grille and observe Warm product loaded into cabinet Blocked condenser Remove and clean the condenser filter Chec...

Page 16: ...er Remove and clean the condenser filter Check that the condenser is free of debris If the coil is dirty clean it with a vacuum cleaner or soft brush Product blocking cabinet airflow Check if the retu...

Page 17: ...rameter settings Controller or circuit The controller may be reading incorrectly and need replacing 26 Controller hardware failure Controller hardware has failed Parameters Load the correct parameter...

Page 18: ...nal For security purposes an optional lockable security grille is available The security grille fits in the front opening of the cabinet and is locked by two keyed security bolts For convenience both...

Page 19: ...and lock with the security key see below 5 To remove the security grille reverse the fitting instructions steps 1 to 4 above Procedure 7 To remove the kick panel 1 Disconnect the cabinet from the pow...

Page 20: ...tabs of the side panels into the top slots of the rear panel and clipping each end tag of the rear panel into the retaining slot in the side panels Fix the two screws back into each side of the rear...

Page 21: ...n reassemble in the order the components were removed Removing the cladding Follow the procedures one after the other to remove the cladding 1 Kick panel see page 19 2 Lit sign and sign sides for high...

Page 22: ...ected when moving the shelves or replacing the lights Procedure 11 To remove the side cladding 1 Remove the kick panel see page 19 and sign see page 20 2 Undo the fixing screws on the back edge of the...

Page 23: ...nates possible electromagnetic interference before feeding it into the refrigeration cartridge 6 Refit the gravity feed matting and dividers see page 8 7 Test and tag as per standard procedure 8 Recon...

Page 24: ...tch mechanism is made up of a magnet in the night blind handle and a switch fitted to a bracket at the bottom right hand side of the cabinet opening The switch cable is connected to the cartridge Nigh...

Page 25: ...and electrical systems Ensure your work area is well ventilated Safety hazards The main hydrocarbon safety hazards are Flammability Venting of hydrocarbon and compressor oil Asphyxiation 6 Remove the...

Page 26: ...bon refrigerant accurate to 1 gram Leak detector A leak detector is used to track and locate the source of hydrocarbon gas leaks It is recommended for servicing hydrocarbon units on site required for...

Page 27: ...binet For safety and compliance only repair the cartridge with SKOPE supplied parts made specifically for this cabinet Other parts may appear to be suitable but may not be approved or safe for use in...

Page 28: ...low the steps below to remove the refrigeration cartridge Table 6 Cartridge specifications Cartridge model UBQENI 0052 Compressor Embraco NT6230U Nominal capacity 2100 watts Refrigerant R290 Charge 15...

Page 29: ...ting levers and rotate inwards to a horizontal position to lower the refrigeration cartridge evaporator tub Remove 2 thumb screws from the plinth cross member 4 Pull the cartridge out approximately 20...

Page 30: ...e electrics box 1 Disconnect the cabinet from the power supply see page 18 2 Remove the kick panel see page 19 3 The cartridge electrics box itself can now be accessed 4 Remove 4 screws from the front...

Page 31: ...hat the blade screw is tightened to 1 5 Nm 4 Remove 6 screws from the electrics box 2 screws on the left side of the electrics box 1 screw above the controller 3 screws on the right side of the electr...

Page 32: ...ove the condenser fan assembly see To access and remove the condenser fan assembly 2 Remove the screw and washer from the centre of the fan blade and lift the blade from the motor 3 Fit the new blade...

Page 33: ...rom the power supply see page 18 2 Remove the refrigeration cartridge see page 28 3 Remove the screw and washer from the centre of the fan blade and lift the blade from the motor 4 Ensure the new blad...

Page 34: ...towards the right side of the evaporator tub once reinstalled Re cable tie the fan cord back onto the mounting bracket to prevent high frequency vibration 8 Place back into the evaporator tub and ens...

Page 35: ...t from the power supply see page 18 2 Remove the front kick panel see page 19 3 Remove the cartridge electrics box see page 30 4 Remove the fixing screws from the electronic controller mounting and pu...

Page 36: ...ete select MENU DISCONNECT to save the parameter set on SCS Connect Field app 15 Power cycle the controller and check that the parameter set has been applied 16 Open the SCS Connect Field app and re c...

Page 37: ...e the cabinet and check for correct operation by connecting to the fridge with the SCS Field app and confirming Motion appears when waving in front of the PIR sensor and No Motion appears when there i...

Page 38: ...he electrics box black plug 6 Remove the evaporator probe from the cartridge cutting cable ties where necessary 7 Following the same path as the original probe run the new probe to the original locati...

Page 39: ...g it 6 Following the same path as the original probe run the new probe to the condenser coil and secure with cable ties Use cork tape to insulate the probe Ensure the probe cable is securely plugged i...

Page 40: ...erial number are both printed on the cartridge rating serial number label attached to the front of the cartridge Before ordering spare parts take note of the model and serial numbers Cabinet 1 2 3 3 4...

Page 41: ...ssembly top O11CLN 590B 32 O11CLN 590B 49 O11CLN 590B SS 18 Shelf support bracket STY12512 49 STY12512 32 SSY12568L SSY12568R 19 Braked swivel castor SXX4539 SXX4539 SXX4539 20 Swivel castor SXX4339 S...

Page 42: ...19 18 4 2 3 4 21 0 Table 8 Parts Refrigeration Cartridge Item Description SKOPE Part No White Black Stainless steel 0 Cartridge UBQENI 0052 P UBQENI 0052 P UBQENI 0052 P 1 Condenser coil CLS12068 CLS...

Page 43: ...ondensate line UT03N00021 UT03N00021 UT03N00021 15 Lifting arm UX01N00002 UX01N00002 UX01N00002 16 Evaporator tub UA0500019 UA0500019 UA0500019 17 Evaporator coil CLS12473 CLS12473 CLS12473 18 Evapora...

Page 44: ...electrics box UA0300046 UA0300046 UA0300046 1 Controller ELZ11749 1632 ELZ11749 1632 ELZ11749 1632 2 Electrics box lid US07N00022 49 US07N00022 49 US07N00022 49 3 LED power supply ELZ12205 ELZ12205 EL...

Page 45: ...T61BS SS 1 Wiring cover high sign O11CLN T67B 32 O11CLN T67B 49 O11CLN T67BS SS1 2 Sign reflector high sign O11CLN T63B 32 O11CLN T63B 32 O11CLN T63B 32 3 Sign end extrusion high sign O11CLN S89B O11...

Page 46: ...61AS SS 1 Wiring cover low sign O11CLN T67A 32 O11CLN T67A 49 O11CLN T67AS SS1 2 Sign reflector low sign O11CLN T63A 32 O11CLN T63A 32 O11CLN T63A 32 3 Sign end extrusion low sign O11CLN S89A O11CLN S...

Page 47: ...the condenser filter 1 Disconnect the cabinet from the power supply see page 18 2 To remove the filter use the finger loops to pull the filter up and detach from the front panel 3 Clean the filter wit...

Page 48: ...closed Switch the light on via the light button on the electronic controller faceplate or via the app Open the night blind Failed LED light Replace the light Refrigeration system error indicated by t...

Page 49: ...ht mode Change the cabinet into Day mode by pressing and holding the light button on the electronic controller faceplate Setpoint is too high Lower the setpoint Recently loaded Allow the product time...

Page 50: ...SKOPE Contacts SKOPE Industries Limited ABN 73 374 418 306 AU 1800 121 535 NZ 0800 947 5673 skope skope com www skope com...

Reviews: