![Skope OD1100N Service Manual Download Page 29](http://html1.mh-extra.com/html/skope/od1100n/od1100n_service-manual_1289215029.webp)
29
SKOPE OD1100N
Replacement Procedures
Service Manual
Cartridge
Electrics Box
The cartridge electrics box contains the electronic controller, the mains supply socket, the LED
power supply, and panel mounted socket connectors. The lights socket, night blind socket, and
PIR sensor socket are on the outside of the cartridge electrics box. These have to be
disconnected when the cartridge is removed. The probe and condenser fan sockets are visible
behind the electrics box front cover. The compressor and evaporator fan sockets are behind
the electrics box. They can be accessed by:
removing the cartridge’s side cover.
lifting up the evaporator tub.
undoing the screws and pulling the electrics box out slightly.
3. Pull the two cartridge lifting levers
and rotate inwards to a horizontal
position to lower the refrigeration
cartridge evaporator tub. Remove
2 × thumb screws from the plinth
cross member.
4. Pull the cartridge out approximately
200 mm. The cartridge weighs
64 kg, so use the handles (see the
drawing details). Unplug all
electrical connections.
5. Using the hand holds, remove the
cartridge from the cabinet. When
removing, take care with loose
plugs, cables, and the cartridge
sealing gasket.
Important
: Ensure the cartridge
remains level when it is removed
from the cabinet to avoid damage to
the cartridge seals.
6. When refitting the refrigeration cartridge, ensure that:
•
the cartridge sealing gasket on top of the cartridge is in good condition.
•
all plugs are securely re-connected.
•
the refrigeration cartridge evaporator tub lifts and seals correctly against the cabinet.
•
you refit the kick panel.
Procedure 16: To remove the refrigeration cartridge (continued)
2 × thumb screws