25
SKOPE OD1100N
Replacement Procedures
Service Manual
Refrigeration System
Before
Servicing
Overview
Ensure you have read and understood this manual before starting any servicing.
Important.
SKOPE hydrocarbon refrigeration systems must only be serviced by appropriately skilled
and qualified refrigeration mechanics.
Servicing a sealed refrigeration system must occur at a hydrocarbon workshop or service
area with dedicated hydrocarbon equipment and personal protective equipment (PPE).
All local hydrocarbon storage and handling regulations and procedures must be followed at
all times.
Ensure all electronic controller alarms diagnostics and refrigeration system diagnostics are
performed to confirm a refrigeration system fault is present.
Check all components including the electronic controller and electrical systems.
Ensure your work area is well ventilated.
Safety hazards
The main hydrocarbon safety hazards are:
Flammability
Venting of hydrocarbon and compressor oil
Asphyxiation
6. Remove the right hand night blind bracket (with the night blind sensor switch fitted):
•
Undo the 2 × fixing screws and remove the return air grille.
•
Undo the 2 × screws and remove the PIR sensor bracket.
•
Undo the remaining 1 × screw and remove the right hand night blind sensor switch bracket.
7. Undo the two fixing screws and
remove the night blind sensor
switch from the bracket.
8. Fit the new night blind sensor switch.
9. Run the new night blind sensor switch cable back and reconnect to the cartridge.
10. Reassemble the fridge and check for correct operation.
Procedure 14: To replace the night blind sensor switch (continued)
2 × fixing screws
IMPORTANT
Use only dedicated hydrocarbon SKOPE OEM spare parts.
DO NOT
use alternative parts.
For safety compliance, use only SKOPE-supplied components
specified for the appliance.