108
TROUBLESHOOTING
SYMPTOM:
Engine turns over but fails to start.
POSSIBLE CAUSES
WHAT TO DO
1. Ignition switch, engine cut-out switch
or tether switch is in the OFF position.
Place all switches in the ON position.
2. Mixture not rich enough to start cold
engine.
Check fuel tank level and check starting
procedure, particularly use of the primer
or the choke.
3. Flooded engine
(spark plug wet when removed).
Do not prime or choke. Remove wet
spark plug, turn ignition switch to OFF
and crank engine several times. Install
clean dry spark plug. Start engine fol-
lowing usual starting procedure. If en-
gine continues to flood, see an autho-
rized SKI-DOO dealer.
4. No fuel to the engine
(spark plug dry when removed).
Check fuel tank level; turn fuel valve on
if applicable; check fuel filter; replace if
clogged; check condition of fuel and im-
pulse lines and their connections. A fail-
ure of the fuel pump or carburetor has
occurred. Contact an authorized SKI-
DOO dealer.
5. Spark plug/ignition
(no spark).
Remove spark plug(s) then reconnect to
spark cap. Check that engine cut-out
switch is at the ON position and the teth-
er cut-out switch cap is snapped over the
receptacle. Start engine with spark
plug(s) grounded to engine away from
spark plug hole. If no spark appears, re-
place spark plug. If trouble persists, con-
tact an authorized SKI-DOO dealer.
6. Engine compression.
As the engine is pulled over with the re-
wind starter, “cycles” of resistance should
be felt as piston goes past top dead cen-
ter (each piston on twin-cylinder en-
gines). If no pulsating resistance is felt,
it suggests a major loss of compression.
Contact an authorized SKI-DOO dealer.
Mmo2002-001a.book Page 108 Friday, January 12, 2001 1:56 PM
Summary of Contents for Skandic LT 2002
Page 1: ......
Page 23: ...21 Instruction 2 SINGLE SEAT MODELS A01A2CA...
Page 24: ...22 Instruction 2 DOUBLE SEAT MODELS A01A2DA...
Page 25: ...23 Instruction 3 ALL MODELS Instruction 4 ALL MODELS A01A2EA A01A2FA...
Page 28: ...26 SKANDIC LT 2 10 16 15 14 13 19 18 5 9 1 12 11 23 4 21 22 17 23 6 7 3 A29H10A 32...
Page 31: ...29 TYPICAL Step Squeeze and hold Step Fully pull A25H30A 1 2 1 2...
Page 48: ...46 Skandic WT SWT WT LC FUSE FOR ELECTRIC POWER OUTLET 1 Fuse holder 1 A29I03A...
Page 71: ...69 SKANDIC LT 1 Hook up starter clip 1 A29D2BA...
Page 80: ...78 TYPICAL 1 Dipstick 2 Oil level 3 Level between marks A03D2MA 1 2 3 1...
Page 89: ...87 Tundra R Disconnect driven pulley support TUNDRA R 1 Raise A05D0PB 1...
Page 119: ......