12.2.3
Configuring the Connection Initiation
The modem must be configured to connect to the network.
To do this, open BlueVue Device Manager and navigate to
WAN (WAN Settings)
, and then ensure that the following
settings are applied:
1)
The Dial String is
#777
for CDMA networks and *99***1# or *99# for GSM networks
2)
The Connection Initiation is
Always On
(default setting for firmware 3.60 and later)
Click
Submit
to apply any changes. The modem should now connect to the cellular network. Refer to this section’s
introduction for instructions on how to verify whether your modem is connected to the network or not.
12.2.4
Configuring the User Profile
If the modem’s
Signal LED turns on
for a few seconds then
turns off
, this indicates that
authentication
on the cellular
network is
failing
. The modem’s User Profile will need to be configured.
Navigate to
WAN (WAN Settings)
. Enter the
user name
and
password
as provided by the cellular service provider.
12.2.5
Conclusion
As mentioned previously, when the modem is connected to the cellular network, BlueVue Device Manager’s Modem
Diagnostic screen will display a
valid WAN IP
and the
WAN LED will remain on and flashing to indicate activity of the
cellular interface
.