30
SAFETY FUNCTIONS AND ERROR SIGNALS
ERROR CODE
ERROR DESCRIPTION
INSTRUCTION MANUAL
E03 + continuous
tone, or XXX
Permanent use of keys; Control unit
cuts off after 10 sec. Water or cooking
utensils on the glass above the control
unit.
Cleaning of the operational surface.
If the problem persists, Contact
authorized center for technical
assistance - specifying the error code.
E21
Control unit cuts off after controlling
due to overheating to avoid damage to
electronics.
Contact authorized center for
technical assistance - specifying the
error code.
E22 or Er22
Defective Key evaluation. Control unit
cuts. Short-circuit or discontinuation in
the range of the key evaluation.
Contact authorized center for
technical assistance - specifying the
error code.
E20 or Er20
Flash-failure faulty. Microcontroller
faulty.
Contact authorized center for
technical assistance - specifying the
error code.
E36 or Er36
Control unit cuts off. Short-circuit
Contact authorized center for
technical assistance - specifying the
error code.
E31 or Er31
Configuration data incorrect.
Configuration of induction necessary.
Contact authorized center for
technical assistance - specifying the
error code.
E47 or Er47
Communication error between TC and
induction.
Contact authorized center for
technical assistance - specifying the
error code.
E2
Overheating of the induction coils.
Contact authorized center for
technical assistance - specifying the
error code.
EA
Error on the power board. Component
failure.
Contact authorized center for
technical assistance - specifying the
error code.
U400
Secondary voltage of the power unit
to high (primary > 300V). Control
unit cuts off after 1 sec releasing
a permanent tone. Control unit is
wrongly connected.
1) Contact authorized center for
technical assistance - specifying the
error code.
2) Contact an electrician check your
home network.
E5
Error on filter board.
Contact authorized center for
technical assistance - specifying the
error code.
E6
Error on power unit.
Contact authorized center for
technical assistance - specifying the
error code.
E8
Incorrect fan speed; error on fan left or
right.
Air exhaust blocked, for example by
paper.
Contact authorized center for
technical assistance - specifying the
error code.
E9
Coil temperature sensor defective.
Contact authorized center for
technical assistance - specifying the
error code.
Summary of Contents for S-DDH1.1
Page 6: ...6 TECHNICAL DRAWING...
Page 38: ...38 INSTALLATION GUIDE FIG 1 FIG 3 FIG 5 FIG 2 FIG 4 FIG 6...
Page 39: ...39 FIG 7 FIG 9 FIG 11 FIG 8 FIG 10 FIG 12...
Page 40: ...40 FIG 13 FIG 15 FIG 14 FIG 16...
Page 44: ...44...