TC620-PID
Page 38
In case of an installation without VDG Sense, the Siqura VCA Configuration Server (Siqura VCS)
can be used to extend the number of VCA features.
The VCA features available together with the Siqura VCS are:
Super fast forensic search on the recorded images
8x Multipoint detection zones
4x Multipoint detection lines, direction sensitive
Perspective, minimum and maximum object size
Object life time and displacement
Counting
(Remote) PID Fine tuning
9.1.3
Configuration methods
The PID functionality on the TC620-PID can be set up from the PID page in the following ways.
Use
Web configuration
to configure settings on the fly.
Use
Expert configuration
to upload an external configuration file containing predefined
settings to the unit.
9.1.4
Web configuration
Configuring PID from the webpage involves the following steps.
1. Enable web configuration
2. Select a detection type
3. Set up the detection layout
4. Configure zone and line properties
5. Configure event settings
Note:
After you have gone through the steps above it may take a few minutes before PID
performance is optimal. The TC620-PID uses this time to process the scene, the detection
layout, and the event settings.
9.1.4.1
Enable web configuration
To enable Web configuration
In the
PID
section, (if necessary) click
Web configuration
.
The preview and various buttons, options, and parameters are now available for
configuration.
9.1.4.2
Set the detection type
Perimeter intrusion can be detected using zones or lines. It is not possible to use the two types
simultaneously.
To select a detection type
1. In
Web configuration
, click to open the
Detection using
list
2. Select either
zones
or
lines
.
The associated shape button is displayed to the left of the preview.