30
Function
Code
Name
Default
Property
Setting
Range
○
○
○
○
○
○
F06.10
AO
output
selection
F06.11
F06.12
F06.13
F06.14
F06.15
Lower output
limit of AO
Corresponding
AO output of
lower limit
Upper output
limit of AO
Corresponding
AO output of
upper limit
Ao output filter
time
0: Running frequency
1: Set frequency
2: Ramp reference frequency
3: Running
speed
4: Output current (relative to
AC drive rated current)
5: Output current (relative to motor
rated current)
6: Output voltage
7: Output power
8: Reserve
9: Output
torque
10: Analog
AI1
input value
11: Reserve
12: Reserve
13: High-speed pulse HDI input value
14: MODBUS
communication
setting value 1
15: MODBUS
communication
setting value 2
0
0.0%~F06.13
0.00~10.00V
F06.11~100.0%
0.00~10.00V
0.000~10.000s
0.0%
0.00V
100.0%
10.00V
0.000s
Group F07 HMI Group
F07.00
User’s
password
0~65535
0
F07.01
S key function
selection
1
0: No function
1: Jog
running
2: Shift the display state by the
shifting key
3: Shift
between
forward rotations
and
reverse
4:
Clear
UP/DOWN
settings
5: Coast to stop
6: Command source switch
◎
○
Function Parameters Table